High-resolution X-ray computed tomographic scanning of the human stapes footplate.
نویسندگان
چکیده
OBJECTIVES The mechanical behaviour of the footplate and its annular ligament depends critically on their shape and orientation in the oval window, but accurate measurements have been difficult to make owing to their small size. Our aims are to visualize the footplate at high resolution and understand its dynamics. METHODS The human cadaver stapes footplate was dissected, and very high-resolution x-ray computed tomographic (CT) scans, with voxel sizes from 4 to 8 pm, were performed. Locally developed software was used to reconstruct the images. RESULTS The data permit us to explore minor details of shape and orientation. The footplate looks like a footprint, and the annular ligament has variable thickness, with a cleft (groove) in its anterior attachment to the oval window. The CT data also permit us to create a three-dimensional finite-element model that can simulate footplate motion. CONCLUSIONS The results obtained lead to further understanding of the mechanical behaviour of the footplate and the annular ligament.
منابع مشابه
High-resolution x-ray CT scanning of the human stapes footplate
Objectives: The mechanical behaviour of the footplate and its annular ligament depends critically on their shape and orientation in the oval window, but accurate measurements have been difficult to make due to their small size. Our aims are to visualize the footplate at high resolution and understand its dynamics. Methods: The human cadaver stapes footplate was dissected and very high resolutio...
متن کاملA Rare Stapes Abnormality
The aim of this study is to increase awareness of rare presentations, diagnostic difficulties alongside management of conductive hearing loss and ossicular abnormalities. We report the case of a 13-year-old female reporting progressive left-sided hearing loss and high resolution computed tomography was initially reported as normal. Exploratory tympanotomy revealed an absent stapedius tendon and...
متن کاملReliability of high-resolution CT scan in diagnosis of otosclerosis.
OBJECTIVE To assess the reliability of high-resolution computed tomographic scan (HRCT scan) for the diagnosis of otosclerosis and to determine its usefulness to predict hearing deterioration and surgical difficulties. STUDY DESIGN Prospective study. SETTING Tertiary reference center. PATIENTS Two hundred nine ears (200 patients) presenting progressive conductive hearing loss with normal ...
متن کاملCongenital Stapes Anomalies with Normal Eardrum
OBJECTIVES A non-progressive and conductive hearing loss with normal eardrum, but no history of trauma and infection, is highly suggestive of a congenital ossicular malformation. Among ossicular anomalies, stapes anomaly is the most common. The purpose of this study is to describe patterns of stapes anomaly and to analyze its surgical outcome with special reference to its patterns. METHODS We...
متن کاملOptical and tomographic imaging of a middle ear malformation in the bullfrog (Rana catesbeiana).
Using a combination of in vivo computerized tomography and histological staining, a middle ear anomaly in two wild-caught American bullfrogs (Rana catesbeiana) is characterized. In these animals, the tympanic membrane, extrastapes, and pars media (shaft) of the stapes are absent on one side of the head, with the other side exhibiting normal morphology. The pars interna (footplate) of the stapes...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of otolaryngology
دوره 33 4 شماره
صفحات -
تاریخ انتشار 2004