A backprojection-filtration algorithm for nonstandard spiral cone-beam CT with an n-PI-window.
نویسندگان
چکیده
For applications in bolus-chasing computed tomography (CT) angiography and electron-beam micro-CT, the backprojection-filtration (BPF) formula developed by Zou and Pan was recently generalized by Ye et al to reconstruct images from cone-beam data collected along a rather flexible scanning locus, including a nonstandard spiral. A major implication of the generalized BPF formula is that it can be applied for n-PI-window-based reconstruction in the nonstandard spiral scanning case. In this paper, we design an n-PI-window-based BPF algorithm, and report the numerical simulation results with the 3D Shepp-Logan phantom and Defrise disk phantom. The proposed BPF algorithm consists of three steps: cone-beam data differentiation, weighted backprojection and inverse Hilbert filtration. Our simulated results demonstrate the feasibility and merits of the proposed algorithm.
منابع مشابه
Katsevich-Type Algorithms for Variable Radius Spiral Cone-Beam CT
To solve the long object problem, an exact and efficient algorithm has been recently developed by Katsevich. While the Katsevich algorithm only works with standard helical cone-beam scanning, there is an important need for nonstandard spiral cone-beam scanning. Specifically, we need a scanning spiral of variable radius for our newly proposed electron-beam CT/micro-CT prototype. In this paper, f...
متن کاملExact Interior Reconstruction with Cone-Beam CT
Using the backprojection filtration (BPF) and filtered backprojection (FBP) approaches, respectively, we prove that with cone-beam CT the interior problem can be exactly solved by analytic continuation. The prior knowledge we assume is that a volume of interest (VOI) in an object to be reconstructed is known in a subregion of the VOI. Our derivations are based on the so-called generalized PI-se...
متن کاملHelical cone-beam computed tomography image reconstruction algorithm for a tilted gantry with N-PI data acquisition
Guang-Hong Chen University of Wisconsin–Madison Department of Medical Physics Madison, Wisconsin 53704 and University of Wisconsin–Madison Department of Radiology Madison, Wisconsin 53792 E-mail: [email protected] Abstract. We present a cone-beam image reconstruction algorithm for helical CT scanning with a tilted gantry and N-PI data acquisition. When the gantry is tilted, the effective source t...
متن کاملPI-line-based image reconstruction in helical cone-beam computed tomography with a variable pitch.
Current applications of helical cone-beam computed tomography (CT) involve primarily a constant pitch where the translating speed of the table and the rotation speed of the source-detector remain constant. However, situations do exist where it may be more desirable to use a helical scan with a variable translating speed of the table, leading a variable pitch. One of such applications could aris...
متن کاملA unified framework for exact cone-beam reconstruction formulas.
In this paper, we present concise proofs of several recently developed exact cone-beam reconstruction methods in the Tuy inversion framework, including both filtered-backprojection and backprojection-filtration formulas in the cases of standard spiral, nonstandard spiral, and more general scanning loci. While a similar proof of the Katsevich formula was previously reported, we present a new pro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 50 9 شماره
صفحات -
تاریخ انتشار 2005