Experimental results of the tracheoesophageal tissue connector for improved fixation of shunt valves in laryngectomized patients.
نویسندگان
چکیده
BACKGROUND After total laryngectomy and voice rehabilitation using a tracheoesophageal shunt valve, patients often have valve-related complications such as leakage. To solve these problems, a tracheoesophageal tissue connector (TE-TC) was devised to serve as an interface between the patient's tissue (trachea and esophagus) and the shunt valve. METHODS The TE-TC is a permucosal connection constructed from a titanium ring (filled with a silicon rubber plug) combined with polypropylene or titanium mesh. After implantation in adult goats for 12 weeks the implants were submitted to histologic investigation. RESULTS Firm implant fixation was achieved. In nearly all (18/19), no signs of infection of the implant were seen; 11 of 19 animals died before the end of the experiment owing to complications not related to the implant. CONCLUSIONS The TE-TC is a new device with potential in the solution for fixation-related problems in tracheoesophageal voice rehabilitation.
منابع مشابه
Clinical evaluation of a membrane-based voice-producing element for laryngectomized women.
BACKGROUND A newly developed artificial voice source was clinically evaluated in laryngectomized women for voice quality improvements. The prosthesis was placed in a commercially available, tracheoesophageal shunt valve. METHODS In 17 subjects, voice-producing element (VPE) prototypes were compared with the subject's regular tracheo-esophageal shunt voice in a randomized cross-over trial. The...
متن کاملComunicação oral de laringectomizados com prótese traqueoesofágica: análise comparativa pré e pós-treino****** Oral communication of laryngectomized patients with tracheoesophageal prosthesis: pre and post-treatment comparative analysis
Background: speech and voice training for laryngectomized patients with tracheoesophageal prosthesis. Aim: to compare the quality of oral communication of a group of laryngectomized patients with tracheoesophageal prostheses, pre and post speech and voice training. Method: voice and speech samples of 17 laryngectomized patients were analyzed before and after receiving speech and voice training....
متن کاملA Technique for Treatment of Overdrainage in Ventriculoperitoneal Shunt
Background and Importance: Overdrainage is a complication of ventriculoperitoneal shunt but adjustable valves and anti-siphon devices can prevent it. These very expensive valves are most often inaccessible, so that the majority of the valves available in Togo are fixed differential pressure valves. Although overdrainage is a widely-known issue, we aimed to introduce a new risk factor and the wa...
متن کاملIn vitro evaluation of a double-membrane-based voice-producing element for laryngectomized patients.
BACKGROUND A sound generator based on a double-membrane design that fits into a regular tracheoesophageal shunt valve may improve voice quality after total laryngectomy in patients rehabilitated with surgical voice prostheses. METHODS Voice-producing element (VPE) prototypes were manufactured using medical grade biocompatible materials and tested in vitro under physiological conditions. RES...
متن کاملExperimental study of hydrodynamic characteristics of improved sieve tray with push valves
This paper addresses an experimental investigation in the hydrodynamic behavior of a modified slotted sieve tray. Slotted sieve tray (Push valve sieve tray) is a sieve tray that the push valves have been utilized on the tray deck to eliminate liquid gradients and non-uniformity of liquid distribution on the tray. The air-water system was used in an industrial scale experimental rig with an inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Head & neck
دوره 28 11 شماره
صفحات -
تاریخ انتشار 2006