Anterior and posterior axial lens displacement and human aqueous outflow facility.
نویسندگان
چکیده
We studied the effect of anterior and posterior axial crystalline lens displacement (and thereby ciliary tone) on the aqueous humor outflow facility in enucleated human eyes. After attaching a reversible footplate plunger to the anterior lens capsule with cyanoacrylate, the lens was placed in one of three positions: "neutral baseline," posterior displacement (2.5 mm), or anterior displacement (2.0 mm). In seven pairs of eyes, the mean "neutral baseline" was not statistically different from the control eye, but anterior lens displacement decreased outflow facility "C" by 0.14 (36%) (P less than 0.0001), and posterior displacement increased "C" by 0.18 (50%) (P less than 0.01). Anterior or posterior lens displacement after complete ciliary body detachment produced no effect on outflow facility in two pairs. Histologic correlation studies demonstrated narrowing of the intertrabecular spaces and Schlemm's canal in the eyes fixed in anterior lens displacement, and widening of the same structures in the eyes fixed in posterior lens displacement. The lens-zonular-ciliotrabecular force vectors are responsible for the compression or decompression of the meshwork and Schlemm's canal in this model, with compression decreasing, and decompression increasing aqueous humor outflow facility.
منابع مشابه
Understanding trabecular meshwork physiology: a key to the control of intraocular pressure?
he anterior and posterior chambers of the eye are filled with aqueous humor, a fluid with an ionic composition very similar to the blood plasma and with two main functions: to supply nutrients to the avascular structures of the eye, cornea, and lens and to maintain intraocular pressure (IOP) within its physiological range, because it is the volume of aqueous humor in the eye chambers that deter...
متن کاملEffect of cataract extraction and posterior chamber lens implantation on outflow facility and its response to pilocarpine in Korean subjects.
AIM To investigate the effect of the lens on outflow facility in Korean patients with cataracts. METHODS Intraocular pressure was measured by Goldmann applanation tonometry in 42 patients with cataracts and outflow facility was determined by tonography preoperatively, before and after instillation of pilocarpine. All patients received clear corneal phacoemulsification and silicone foldable in...
متن کاملNumerical Analysis of the Thermal Interaction of Cell Phone Radiation with Human Eye Tissues
Introduction: The present study aimed to present a numerical analysis of the penetration depth, specific absorption rate (SAR), and temperature rise in various eye tissues with varying distance between radiation source and exposed human eye tissues (i.e., cornea, posterior chamber, anterior chamber, lens, sclera, vitreous humor, and iris) at frequencies of 900 and1800 MHz. Materials and Method...
متن کاملThe canine eye: lens depression and aqueous outflow.
The effects on facility of outflow of lens depression (controlled mechanical retrodisplacement of the crystalline lens to simulate cyclotonia in excised eye preparations), prolonged perfusion, and intracameral hyaluronidase were evaluated in 16 pairs of freshly excised canine eyes. Lens depression increased facility of aqueous outflow by an amount greater than could be attributed to mechanical ...
متن کاملChoroid tension and facility of aqueous outflow.
Tension of the choroid of enucleated eyes was adjusted by incising the sclera and lengthening the eye. The facility of outflow increased in direct proportion to choroid stretch. The present results are compared with reported results of anterior chamber deepening and lens depression in vitro and with accommodation and goniospasis in vivo. Choroid stretch in the enucleated eye is less efficient i...