Detection of internal thoracic artery dissection at coronary anastomosis using intraoperative 15-MHz high-frequency epicardial ultrasound.
نویسندگان
چکیده
A 66-year-old man with a history of diabetes mellitus presented with angina pectoris with 3-vessel disease, and he underwent off-pump coronary artery bypass grafting via median sternotomy. After performing bypass grafting of the left internal thoracic artery to the left anterior descending artery, the appearance of anastomosis configuration appeared to be acceptable. However, transit time flow measurement (TTFM) showed that the mean graft flow was 10 mL/min, which was less than expected despite an acceptable flow curve with a diastolic flow pattern, a pulsatility index (index of resistance) of 2.0, and diastolic filling (proportion of diastole with coronary flow) of 65% (Figure 1). In addition to TTFM, the anastomosis was evaluated by using 15-MHz high-frequency epicardial ultrasound (VeriQ C system; Medistim, Oslo, Norway). It accurately detected an intimal flap of the left internal thoracic artery at the anastomosis site, and the restricted flow pattern in the true lumen was visualized by using Doppler color flow mapping (Figure 2; Movie I in the online-only Data Supplement). The anastomosis was successfully revised, with the use of TTFM to confirm an adequate flow value of 36 mL/ min (Figure 3) and epicardial ultrasound to confirm a good configuration of the anastomosis. There is growing concern regarding the increased risk of errors in anastomosis construction during off-pump coronary artery bypass grafting because the suturing process is technically more demanding than that in surgery on the arrested heart. The European Society of Cardiology/European Association for Cardio-Thoracic Surgery guidelines on myo-cardial revascularization recently recommended intraoperative graft evaluation using TTFM. 1 However, graft flow measurement can only detect severe stenosis (>75%) and provides no information regarding anastomosis configuration; thus, the number of suboptimal anastomoses may be underestimated. In recent years, we introduced an approach using 15-MHz high-frequency epicardial ultrasound to increase diagnostic accuracy relative to that of using TTFM alone. In this case, high-frequency epicardial ultrasound demonstrated its ability to detect an anastomosis error that was not identified by TTFM alone. This approach can be used as a quality-control modality to provide information regarding graft function and anastomosis configuration. Disclosures None.
منابع مشابه
Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.
BACKGROUND Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery...
متن کاملRobot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses.
In totally endoscopic coronary artery bypass surgery, intra-operative assessment of anastomotic quality is needed. We evaluated the endoscopic application of epicardial ultrasound to visualize the coronary anastomosis and detect a construction error. In 8 pigs (71-78kg), 16 internal mammary artery to left anterior descending coronary artery anastomoses were constructed conventionally, either co...
متن کاملGeometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound.
OBJECTIVE There is concern about the quality of the distal anastomosis in off-pump coronary artery bypass grafting. We investigated the impact of specific construction errors on anastomotic geometry using epicardial ultrasound. METHODS Twelve ex vivo pressure perfused porcine and five isolated post-mortem human hearts were used to construct 35 internal mammary artery to coronary artery anasto...
متن کاملIntraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography: experimental validation and initial patient studies.
There is currently no accepted approach for intraoperative evaluation of the technical adequacy of coronary artery bypass graft anastomoses. High-frequency epicardial echocardiography performed intraoperatively could assess coronary artery bypass graft anastomoses by providing on-line short-axis (cross-sectional) and longitudinal two-dimensional images of the vessels. To validate measurements o...
متن کاملHistopathological validation of high frequency epicardial echocardiography of the coronary arteries in vitro.
The accuracy and reliability of measurement of coronary artery dimensions and detection of atherosclerotic lesions by high frequency epicardial echocardiography were compared with histopathological results. Ten pressure perfused human hearts were examined in vitro with a 10 MHz (Diasonics) transducer and a 7.5 MHz (Vingmed/Sonotron) transducer. There was close agreement between ultrasound and p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 129 22 شماره
صفحات -
تاریخ انتشار 2014