Modal control of a plate using a fuzzy logic controller

نویسندگان

  • Manu Sharma
  • S P Singh
  • B L Sachdeva
چکیده

This paper presents fuzzy logic based independent modal space control (IMSC) and fuzzy logic based modified independent modal space control (MIMSC) of vibration. The rule base of the controller consists of nine rules, which have been derived based upon simple human reasoning. Input to the controller consists of the first two modal displacements and velocities of the structure and the output of the controller is the modal force to be applied by the actuator. Fuzzy logic is used in such a way that the actuator is never called to apply effort which is beyond safe limits and also the operator is saved from calculating control gains. The proposed fuzzy controller is experimentally tested for active vibration control of a cantilevered plate. A piezoelectric patch is used as a sensor to sense vibrations of the plate and another piezoelectric patch is used as an actuator to control vibrations of the plate. For analytical formulation, a finite element method based upon Hamilton’s principle is used to model the plate. For experimentation, the first two modes of the plate are observed using a Kalman observer. Real-time experiments are performed to control the first mode, the second mode and both modes simultaneously. Experiments are also performed to control the first mode by IMSC, the second mode by IMSC and both modes simultaneously by MIMSC. It is found that for the same decibel reduction in the first mode, the voltage applied by the fuzzy logic based controller is less than that applied by IMSC. While controlling the second mode by IMSC, a considerable amount of spillover is observed in the first mode and region just after the second mode, whereas while controlling the second mode by fuzzy logic, spillover effects are much smaller. While controlling two modes simultaneously, with a single sensor/actuator pair, appreciable resonance control is observed both with fuzzy logic based MIMSC as well as with direct MIMSC, but there is a considerable amount of spillover in the off-resonance region. This may be due to the sub-optimal location and/or an insufficient number of actuators. So, another smart plate with two piezoelectric actuators and one piezoelectric sensor is considered. Piezoelectric patches are fixed in an area where modal strains are high. With this configuration of the smart plate, experiments are conducted to control the first three modes of the plate and it is found that spillover effects are greatly reduced.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlling Electrochemical Machining By Using a Fuzzy Logic Approach

New trends and the effect of key factors influence the quality of the holes produced by ECM processes. Researchers developed a fuzzy logic controller by adding intelligence to the ECM process. Maintaining optimum ECM process conditions ensures higher machining efficiency and performance. This paper presents the development of a fuzzy logic controller to add intelligence to the ECM process. An e...

متن کامل

Controlling Electrochemical Machining By Using a Fuzzy Logic Approach

New trends and the effect of key factors influence the quality of the holes produced by ECM processes. Researchers developed a fuzzy logic controller by adding intelligence to the ECM process. Maintaining optimum ECM process conditions ensures higher machining efficiency and performance. This paper presents the development of a fuzzy logic controller to add intelligence to the ECM process. An e...

متن کامل

Design and PLC Implementation for Speed Control of DC Motor using Fuzzy Logic

In this article, a speed control of DC motor is designed and illustrated using fuzzy logic-based programmable logic controller (PLC). The DC motor is an attractive part of electrical equipment in many industrial applications requiring variable speed and load specifications due to its ease of controllability. The designed system is consisted of three main parts including programmable logic contr...

متن کامل

Optimal intelligent control for glucose regulation

This paper introduces a novel control methodology based on fuzzy controller for a glucose-insulin regulatory system of type I diabetes patient. First, in order to incorporate knowledge about patient treatment, a fuzzy logic controller is employed for regulating the gains of the basis Proportional-Integral (PI) as a self-tuning controller. Then, to overcome the key drawback of fuzzy logic contro...

متن کامل

Adaptive and intelligent control of permanent magnet synchronous motor (PMSM) using a combination of fuzzy logic and gray wolf algorithm under fault condition

Nowadays, permanent magnet synchronous motors have been widely used in industry due to the elimination of excitation losses, longer life and higher efficiency. Errors in engine and drive systems are unavoidable during operation. Therefore, a suitable scenario should be considered for when these systems fail. If the necessary predictions and control algorithms are not considered for the error co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007