Covalent immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase & horseradish peroxidase onto plasticized polyvinyl chloride (PVC) strip & its application in serum triglyceride determination

نویسندگان

  • Nidhi Chauhan
  • Jagriti Narang
  • Chandra Shekhar Pundir
چکیده

BACKGROUND & OBJECTIVES Reusable biostrip consisting enzymes immobilized onto alkylamine glass beads affixed on plasticized PVC strip for determination of triglyceride (TG) suffers from high cost of beads and their detachments during washings for reuse, leading to loss of activity. The purpose of this study was to develop a cheaper and stable biostrip for investigation of TG levels in serum. METHODS A reusable enzyme-strip was prepared for TG determination by co-immobilizing lipase, glycerol kinase (GK), glycerol-3-phosphate oxidase (GPO) and peroxidase (HRP) directly onto plasticized polyvinyl chloride (PVC) strip through glutaraldehyde coupling. The method was evaluated by studying its recovery, precision and reusability. RESULTS The enzyme-strip showed optimum activity at pH 7.0, 35 o C and a linear relationship between its activity and triolein concentration in the range 0.1 to 15 mM. The strip was used for determination of serum TG. The detection limit of the method was 0.1 mM. Analytical recovery of added triolein was 96 per cent. Within and between batch coefficients of variation (CV) were 2.2 and 3.7 per cent, respectively. A good correlation (r=0.99) was found between TG values by standard enzymic colrimetric method employing free enzymes and the present method. The strip lost 50 per cent of its initial activity after its 200 uses during the span of 100 days, when stored at 4 o C. INTERPRETATION & CONCLUSIONS The nitrating acidic treatment of plasticized PVC strip led to glutaraldehyde coupling of four enzymes used for enzymic colourimetric determination of serum TG. The strip provided 200 reuses of enzymes with only 50 per cent loss of its initial activity. The method could be used for preparation of other enzyme strips also.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preparation of Oxygen Meter Based Biosensor for Determination of Triglyceride in Serum

A method is described for preparation of a dissolved oxygen meter (make Aqualytic, Germany) based triglyceride biosensor employing a polyvinyl chloride (PVC) membrane bound lipase, glycerol kinase (GK) and glycerol-3-phosphate oxidase The biosensor measures dissolved O2 utilized in the oxidation of triglyceride (TG) by membrane bound lipase, glycerol kinase (GK) and glycerol-3-phosphate oxidase...

متن کامل

Co-immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase and peroxidase onto alkylamine glass beads through glutaraldehyde coupling.

A method for co-immobilizing lipase from porcine pancreas, glycerol kinase (GK) from Cellulomonas spp., glycerol-3-phosphate oxidase (GPO) from Aerococcus viridans and peroxidase from horseradish onto zirconia-coated alkylamine glass beads through glutaraldehyde coupling has been described. The co-immobilized enzymes retained 71.4% of initial specific activity with a conjugation yield of 43.6 m...

متن کامل

Co-immobilization of lipase, glycerol kinase, glycerol-3-phosphate oxidase and peroxidase on to aryl amine glass beads affixed on plastic strip for determination of triglycerides in serum.

Commercial lipase, glycerol kinase (GK), glycerol-3-phosphate oxidase (GPO) and peroxidase (POD) have been co-immobilized covalently on to arylamine glass beads affixed on a plastic strip through diazotization with a conjugation yield of 89.1 mg/g support and 64.1% retention of specific activity. The co-immobilized enzymes showed maximum activity at pH 7.5, when incubated at 40 degrees C for 20...

متن کامل

Construction of an amperometric triglyceride biosensor using PVA membrane bound enzymes.

OBJECTIVES A method is described for construction of an amperometric triglyceride (TG) biosensor using PVA membrane bound enzymes. DESIGN AND METHODS A mixture of commercial lipase, glycerol kinase, glycerol-3-phosphate oxidase and horseradish peroxidase was co-immobilized onto polyvinyl alcohol (PVA) membrane through glutaraldehyde coupling. The biosensor measures current when polarized at 0...

متن کامل

Determination of serum triglycerides using lipase, glycerol kinase, glycerol-3-phosphate oxidase and peroxidase co-immobilized onto alkylamine glass beads.

A method for determination of serum triglycerides (Tgs) using lipase, glycerol kinase, glycerol-3-phosphate oxidase and peroxidase co-immobilized onto alkylamine glass beads (pore diameter 55 nm) through glutaraldehyde coupling was developed and evaluated. The minimum detection limit of the method was 0.54 mM. The analytical recovery of added triolein in the serum was 97.55 +/- 1.5% (mean +/- S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 139  شماره 

صفحات  -

تاریخ انتشار 2014