The Swan-Ganz catheter in the cardiac laboratory.

نویسندگان

  • P Steele
  • H Davies
چکیده

In I970, Swan and associates reported on their results in catheterization of the right heart with a soft, flow-directed, balloon-tipped catheter of their design. Using the 5F size catheter the pulmonary artery was rapidly and safely catheterized in 95 per cent of patients in intensive care situations without the aid of fluoroscopy. The availability of the Swan-Ganz catheter (Edwards Laboratories, 624 Dyer Road, Santa Ana, California) has led to a change in our approach to cardiac catheterization, and the purpose of this report is to describe our experience with this catheter in routine cardiac catheterization in the cardiovascular laboratory. In the sicker patient, particularly when the right atrium is enlarged, the performance of a right heart catheterization represents in many cases the most hazardous part of the procedure when carried out with orthodox, semi-rigid catheters such as the Cournand or Lehman catheter. The reason for this is the need to form a loop by pushing the catheter against the right atrial wall. Not infrequently this manoeuvre leads to supraventricular tachycardia, and in a proportion of these the whole study is jeopardized or abandoned. Further, frightening ventricular arrhythmias are frequently precipitated by semi-rigid catheters impinging against the right ventricular endocardium. It has, therefore, become our policy to practise and teach that when the important data required are those from the left heart (e.g. coronary arteriography, aortic valve function) the right heart catheter should not be advanced beyond the superior vena cava until the relevant left-sided data have been obtained. With the advent of the Swan-Ganz catheter,

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Latex anaphylaxis caused by a Swan-Ganz catheter.

A 78-year-old woman visited the division of cardiovascular disease in our hospital. She underwent a cardiac catheter examination, and a Swan-Ganz catheter was inserted. Several minutes later, she developed anaphylactic shock. She had no past history of latex allergy, but did have a banana allergy. Skin prick tests showed a positive reaction to an extract of latex gloves and an extract of the ba...

متن کامل

Entrapment of a Swan-Ganz catheter.

Failure to withdraw a catheter is related primarily to catheter entrapment or knotting. Placement of a Swan-Ganz catheter is associated with various complications, one of which is entrapment. Entrapment of a Swan-Ganz catheter in the heart, vena cava, or pulmonary artery is a very rare and serious complication that may lead to life-threatening complications if not treated appropriately. Most re...

متن کامل

Hepatic vein obstruction due to Swan-Ganz catheter placement.

Complications from Swan-Ganz catheters during insertion, long-term placement, or removal have been known since its development. I describe the unusual presentation of a pacing Swan-Ganz catheter mispositioned into the hepatic vein producing vascular obstruction, yet with adequate cardiac pacing.

متن کامل

Assessment of the sterility of long-term cardiac catheterization using the thermodilution Swan-Ganz catheter.

Fifty-seven patients requiring catheterization with a thermodilution Swan-Ganz catheter in the surgical intensive care unit were prospectively studied to determine the incidence and significance of positive pulmonary arterial blood cultures. Nonseptic (group 1) and septic (group 2) patients were identified, with subdivision of the groups into A and B classes contingent upon a negative or posit...

متن کامل

Inadvertent fracture during the attempted removal of entrapped Swan-Ganz catheter.

Dear Editor, Pulmonary artery catheter is widely used in cardiovascular surgical practice. Various complications of the Swan-Ganz catheter during insertion, its long-term placement, or removal are well known since its introduction.1-5 Herein, we report a case of the inadvertent fracture of an entrapped Swan-Ganz catheter during its attempted removal with moderate external traction. A 36-year-ol...

متن کامل