Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results.
نویسندگان
چکیده
Short-lag spatial coherence (SLSC) imaging is a novel beamforming technique that reduces acoustic clutter in ultrasound images. A clinical study was conducted to investigate clutter reduction and endocardial border detection in cardiac SLSC images. Individual channel echo data were acquired from the left ventricle of 14 volunteers, after informed consent and institutional review board approval. Paired B-mode and SLSC images were created from these data. Contrast, contrast-to-noise, and signal-to-noise ratios were measured in paired images, and these metrics were improved with SLSC imaging in most cases. Three cardiology fellows rated the visibility of endocardial segments in randomly ordered B-mode and SLSC cine loops. SLSC imaging offered 22%-33% improvement (p < 0.05) in endocardial border visibility when B-mode image quality was poor (i.e., 80% or more of the endocardial segments could not be visualized by the three reviewers). The percentage of volunteers with poor-quality images was decreased from 21% to 7% with the SLSC beamformer. Results suggest that SLSC imaging has the potential to improve clinical cardiac assessments that are challenged by clutter.
منابع مشابه
Lesion detectability in diagnostic ultrasound with short-lag spatial coherence imaging.
We demonstrate a novel imaging technique, named short-lag spatial coherence (SLSC) imaging, which uses short distance (or lag) values of the coherence function of backscattered ultrasound to create images. Simulations using Field II are used to demonstrate the detection of lesions of varying sizes and contrasts with and without acoustical clutter in the backscattered data. B-mode and SLSC imagi...
متن کاملShort-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.
Prostate brachytherapy, administered by implanting tiny radioactive seeds to treat prostate cancer, currently relies on transrectal ultrasound imaging for intraoperative visualization of the metallic seeds. Photoacoustic (PA) imaging has been suggested as a feasible alternative to ultrasound imaging due to its superior sensitivity to metal surrounded by tissue. However, PA images suffer from po...
متن کاملDevelopment and validation of a short-lag spatial coherence theory for photoacoustic imaging
We previously derived a theoretical expression for spatial coherence in photoacoustic data and utilized it to study properties of the short-lag spatial coherence (SLSC) beamformer applied to photoacoustic imaging. In this paper, an updated version of our theoretical equation is evaluated to generate SLSC images of a point target, a 1.2 mm diameter target, and corresponding lateral profiles thro...
متن کاملImproving the quality of ultrasound images using Bayesian estimators
Medical ultrasound imaging due to close behavior of cancer tumors to body tissues has a low contrast. This problem with synthetic aperture imaging method has been addressed. Although the synthetic aperture imaging technique solved the low-contrast problem of ultrasound images, to an acceptable limit, but the performance of these methods is not even acceptable when the signal to noise ratio (SNR...
متن کاملThe role of myocardial perfusion SPECT in short-term cardiac prognosis of end-stage renal disease
Introduction: One of the most important causes of death in patients with end-stage renal disease (ESRD) and even after kidney transplantation is cardiovascular diseases. Thus, cardiac evaluation is of utmost importance in the management of these patients especially during preoperative work up before renal transplantation. The aim of present study is to evaluate the role of myoc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ultrasound in medicine & biology
دوره 39 10 شماره
صفحات -
تاریخ انتشار 2013