PURPOSE To assess interpretation performance and radiation dose when two-dimensional synthesized mammography (SM) images versus standard full-field digital mammography (FFDM) images are used alone or in combination with digital breast tomosynthesis images. MATERIALS AND METHODS A fully crossed, mode-balanced multicase (n = 123), multireader (n = 8), retrospective observer performance study was performed by using deidentified images acquired between 2008 and 2011 with institutional review board approved, HIPAA-compliant protocols, during which each patient signed informed consent. The cohort included 36 cases of biopsy-proven cancer, 35 cases of biopsy-proven benign lesions, and 52 normal or benign cases (Breast Imaging Reporting and Data System [BI-RADS] score of 1 or 2) with negative 1-year follow-up results. Accuracy of sequentially reported probability of malignancy ratings and seven-category forced BI-RADS ratings was evaluated by using areas under the receiver operating characteristic curve (AUCs) in the random-reader analysis. RESULTS Probability of malignancy-based mean AUCs for SM and FFDM images alone was 0.894 and 0.889, respectively (difference, -0.005; 95% confidence interval [CI]: -0.062, 0.054; P = .85). Mean AUC for SM with tomosynthesis and FFDM with tomosynthesis was 0.916 and 0.939, respectively (difference, 0.023; 95% CI: -0.011, 0.057; P = .19). In terms of the reader-specific AUCs, five readers performed better with SM alone versus FFDM alone, and all eight readers performed better with combined FFDM and tomosynthesis (absolute differences from 0.003 to 0.052). Similar results were obtained by using a nonparametric analysis of forced BI-RADS ratings. CONCLUSION SM alone or in combination with tomosynthesis is comparable in performance to FFDM alone or in combination with tomosynthesis and may eliminate the need for FFDM as part of a routine clinical study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

The use of mammography techniques for the screening and diagnosis of breast cancers has been limited by the overlapping of cancer symptoms with normal tissue structures. To overcome this problem, two methods have been developed and actively investigated recently: digital tomosynthesis mammography and cone beam breast CT. Comparison study with these three techniques will be helpful to understand...

متن کامل

Impact of three dimensional tomosynthesis on the detection and diagnosis of breast lesions

Subjects and methods The study included 166 mammograms with indeterminate findings selected from 1600 mammograms. They were classified into two groups: group 1 ‘Diagnostic mammograms’ of symptomatic women and group 2 ‘Screening mammograms’. Dense breasts assigned as ACR3 and ACR4 presented 69% (n = 114/166) of the studied cases. FFDM and 3D tomosynthesis examination was done and imaging finding...

متن کامل

Registration of Mammograms and Breast Tomosynthesis Images

Digital breast tomosynthesis is becoming a clinically attractive modality based on its potential to combine the high resolution and high contrast images, and affordability of digital mammography, with the advantages of 3D image acquisition. In order to facilitate comparison of tomosynthesis images with previous mammographic exams of the same women, there is a need for a method of registering a ...

متن کامل

Automatic correspondence detection in mammogram and breast tomosynthesis images

Two-dimensional mammography is the major imaging modality in breast cancer detection. A disadvantage of mammography is the projective nature of this imaging technique. Tomosynthesis is an attractive modality with the potential to combine the high contrast and high resolution of digital mammography with the advantages of 3D imaging. In order to facilitate diagnostics and treatment in the current...

متن کامل

Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population.

Purpose To compare the clinical performance of synthesized two-dimensional (s2D) mammography combined with digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) alone and FFDM combined with DBT in a large community-based screening population by analyzing recall rate, positive predictive value, and cancer detection rate. Materials and Methods This was a retrospect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiology

دوره 271 3  شماره 

صفحات  -

تاریخ انتشار 2014