Radiographic exposure slide rules.
نویسنده
چکیده
Before automatic exposure control was fitted to diagnostic X-ray sets, radiographers were faced with the problem of choosing the parameters that would give the best radiographic image. For a new X-ray set whose performance was unknown, this was no easy matter, and often required considerable trial and error because of the number of variables involved. To reduce the amount of work, special slide rules were invented which calculated the effect of some of these variables. Five such slide rules, dating from between about 1910 and 1950, are illustrated and discussed, including the light they shed on changes in radiographic practice over the years.
منابع مشابه
بررسی میزان تکرار تصاویر رادیوگرافی و عوامل مرتبط با آن در مراکز درمانی بخش های دولتی شهرستان ساری در سال 1387
Background and purpose: Radiographic film repeat rate assessment is performed to appropriate profiting of existence resources in therapeutic wards. Multiple exposures of x-ray generators due to repeated radiographic examination can lead to amortization of the radiographic facilities and decrease their longevity and also increases the cost of facilities repair. On the other hand, its therapeut...
متن کاملA study of densitometry comparison among three radiographic processing solutions
ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...
متن کاملThe effects of wall slide and sling slide exercises on scapular alignment and pain in subjects with scapular downward rotation
[Purpose] The present study was performed to evaluate the changes in the scapular alignment, pressure pain threshold and pain in subjects with scapular downward rotation after 4 weeks of wall slide exercise or sling slide exercise. [Subjects and Methods] Twenty-two subjects with scapular downward rotation participated in this study. The alignment of the scapula was measured using radiographic a...
متن کاملRelationship between Radiographic and non-radiographic Factors, and Surgical Complications in impacted mandibular third molar surgery
Background and Aim: Surgical extraction of mandibular third molar is the most prevalent oral surgery. Many factors can affect subsequent complications of it. This study aimed to assess radiographic and non-radiographic factors of impacted mandibular third molar and determine the relationship between these factors and surgical complications. Material and Methods: This study has a prospective coh...
متن کاملبررسی میزان انطباق بخش های رادیوگرافی در بیمارستان های دولتی استان مازندران با راهنمای استاندارد CEC و عوامل مرتبط با آن در سال 1390
Abstract Background and purpose: The Commission of European Communities (CEC) has developed a guideline in which many common radiographic techniques are determined. Following these guidelines will reduce patient dose and good quality image is obtained. Noncompliance of radiographic centers with standard guidelines not only leads to reduction in radiographic image quality but also wastes reso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of radiology
دوره 72 853 شماره
صفحات -
تاریخ انتشار 1999