Automated quantification with BRASS reduces equivocal reporting of DaTSCAN (123I-FP-CIT) SPECT studies.
نویسندگان
چکیده
BACKGROUND ¹²³I-FP-CIT (DaTSCAN) SPECT studies of the nigrostriatal pathway are a valuable tool in the diagnosis of movement disorders. However some scans are reported as equivocal with potential adverse consequences. We investigated whether the use of quantification of tracer uptake within the striatum can be used to reduce the number of equivocal reports. MATERIAL AND METHODS BRASS software (Hermes, Sweden) was used to quantify striatal tracer uptake in DaTSCAN studies of patients referred to our institution. Scans were quantified and numerical limits were determined to distinguish between normal and abnormal scans. Scans were then re-reported both with, and without, the use of quantification. Number of equivocal reports and accuracy of reporting between the two types of reporting were compared. RESULTS Scan reporting using quantification led to a significant reduction in the number of equivocal reports with no significant change in reporting accuracy. CONCLUSION Automated quantification of DaTSCAN studies with BRASS and the use of numerical limits can decrease the number of equivocal reports without affecting report accuracy.
منابع مشابه
The impact of reconstruction and scanner characterisation on the diagnostic capability of a normal database for [123I]FP-CIT SPECT imaging
BACKGROUND The use of a normal database for [123I]FP-CIT SPECT imaging has been found to be helpful for cases which are difficult to interpret by visual assessment alone, and to improve reproducibility in scan interpretation. The aim of this study was to assess whether the use of different tomographic reconstructions affects the performance of a normal [123I]FP-CIT SPECT database and also wheth...
متن کامل123I-FP-CIT brain SPECT (DaTSCAN) imaging in the diagnosis of patients with movement disorders--first results.
BACKGROUND/AIM 123I-FP-CIT brain single-photon emission computed tomography (SPECT), DaTSCAN imaging, offers a possibility to study structural and biochemical integrity of presinaptic dopaminergic neurotransmitter system. The aim of this study was to evaluate the usefulness of 123I-FP-CIT brain SPECT scintigraphy in patients with extrapyramidal diseases. METHODS Fifteen patients (8 males and ...
متن کاملAccurate differentiation of parkinsonism and essential tremor using visual assessment of [123I]-FP-CIT SPECT imaging: the [123I]-FP-CIT study group.
OBJECTIVE To evaluate whether visual assessment of [123I]-FP-CIT (DaTSCAN, Nycomed Amersham, plc) single photon emission computerized tomography (SPECT) images can differentiate between parkinsonism and essential tremor (ET). METHODS [123I]-FP-CIT SPECT imaging was conducted in a six-center study of 158 patients with a clinical diagnosis of parkinsonism compared with 27 ET cases and 35 health...
متن کاملCost-effectiveness of 123I-FP-CIT SPECT in the differential diagnosis of essential tremor and Parkinson's disease in Italy.
Economic evaluation (Italian NHS perspective) modeling (123)I-FP-CIT SPECT (DaTSCAN) compared to clinical judgment alone for differentiating essential tremor (ET) from Parkinson's Disease (PD). A 5-year Markov model was constructed to assess the cost-effectiveness of (123)I-FP-CIT SPECT to differentiate ET from PD in patients referred to a movement disorder specialist in Italy. Published data a...
متن کاملImprovement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database
Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nuclear medicine review. Central & Eastern Europe
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2014