Propagation of blood flow pulse in the normal human pulmonary arterial system. Analysis of the pulsatile capillary flow.

نویسندگان

  • N B Karatzas
  • G de J Lee
چکیده

We studied a number of dynamic events associated with the pulsatile flow of blood in the pulmonary arterial system of six healthy men in the supine position. We used the nitrous oxide-body plethysmograph method to record the pulmonary capillary blood flow pulse and the phonocardiogram to determine the time of opening and closing of the pulmonary valve. The pattern of right ventricular ejection was modified by administration of atropine and isoproterenol and by exercise. The time of conduction of the flow pulse from the pulmonary valve to the lung capillaries averaged 120 msec. Acceleration of capillary blood during systole averaged 8.2 ml/sec/msec. The fraction of stroke volume which distended the pulmonary arterial system during systole averaged 67.2%. The peak flow rate averaged 186 ml/sec. Tachycardia resulted in a decrease in the fraction of the stroke volume stored in the arterial tree during systole. Isoproterenol and exercise resulted in an increase in average capillary blood acceleration. Conduction time is accounted for by pulmonary arterial distensibility, which also allows storage of the ejected blood during systole, which in turn helps to maintain continuity of blood flow in the capillaries. Despite these modifying effects of the pulmonary arterial system upon the flow wave, changes in the pattern of inflow pulse were detectable in the capillary flow pulse. ADDITIONAL

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Propagation of Blood Flow Pulse in the Normal Human Pulmonary Arterial System

We studied a number of dynamic events associated with the pulsatile flow of blood in the pulmonary arterial system of six healthy men in the supine position. We used the nitrous oxide-body plethysmograph method to record the pulmonary capillary blood flow pulse and the phonocardiogram to determine the time of opening and closing of the pulmonary valve. The pattern of right ventricular ejection ...

متن کامل

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

متن کامل

An implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery

With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Pulmonary Capillary Flow Pulse and the Site of Pulmonary Vasoconstriciton in the Dog.

• The amplitude of the capillary pulse is markedly dependent on resistance to blood flow through precapillary vessels. Recent studies by Lee and DuBois indicate that blood flow through the pulmonary capillaries * is normally pulsatile. This result points to the possibility that reactions of pulmonary arterial vessels may be studied by their effects on the amplitude of the pulmonary capillary pu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 25 1  شماره 

صفحات  -

تاریخ انتشار 1969