Original Contributions The Delivery of Chlorofluorocarbon-Propelled Versus Hydrofluoroalkane-Propelled Beclomethasone Dipropionate Aerosol to the Mechanically Ventilated Patient: A Laboratory Study
نویسندگان
چکیده
We describe a laboratory investigation comparing the delivery of chlorofluorocarbon (CFC)and hydrofluoroalkane (HFA)-formulated beclomethasone dipropionate (BDP) by metered-dose inhaler and holding chamber (AeroChamber HC MV) in a simulation of a mechanically ventilated adult patient. METHODS: We equipped each HC MV (n 5) with an 8.0 mm diameter endotracheal tube (ETT), locating the HC MV in the inspiratory limb of a breathing circuit linked to a mechanical ventilator set to simulate tidal breathing at tidal volume 830 mL, respiratory rate 15 breaths/min, inspiratoryexpiratory ratio of 1:2.1, peak inspiratory pressure 20 cm H2O. Temperature and humidity settings were 35 1°C and 100% relative humidity (close to body conditions). We compared delivery of 5-actuations of CFCand HFA-BDP (both 50 g/actuation), measuring total emitted mass captured by a filter at the distal end of the ETT. In a separate study, we inserted the distal end of the ETT within the entry cone of a cascade impactor so that the aerosol particle size distribution could be determined with the circuit at similar environmental conditions as described previously. We made benchmark measurements with circuit temperature and humidity at room ambient conditions (21 1°C and 54 5% RH respectively). RESULTS: Total emitted mass (5 measurements/device) was significantly greater for HFA-BDP (14.1 1.1 g/actuation) compared with CFC-BDP (2.4 0.8 g/actuation) (paired t test, p < 0.001). More HFA-BDP (2.7 0.2 g/actuation) was lost from the delivery system during exhalation (0.9 0.4 g/actuation for CFC-BDP) (p < 0.001). The mass median aerodynamic diameter (MMAD) increased from 1.2 m (room ambient) to 2.8 m (higher temperature and humidity conditions) for HFA-BDP. In contrast, MMAD for CFC-BDP remained close to 4.6 m under either condition, but particles finer than about 4.0 m increased in size when the circuit was saturated. CONCLUSIONS: Total emitted mass for HFA-BDP was increased by a factor of 5.8 compared with CFC-BDP, due largely to the finer particle size distribution of the HFA-based solution formulation. Additional water vapor required to operate the breathing circuit at close to body conditions resulted in fine particle growth with both formulations.
منابع مشابه
The delivery of chlorofluorocarbon-propelled versus hydrofluoroalkane-propelled beclomethasone dipropionate aerosol to the mechanically ventilated patient: a laboratory study.
UNLABELLED We describe a laboratory investigation comparing the delivery of chlorofluorocarbon (CFC)- and hydrofluoroalkane (HFA)-formulated beclomethasone dipropionate (BDP) by metered-dose inhaler and holding chamber (AeroChamber HC MV) in a simulation of a mechanically ventilated adult patient. METHODS We equipped each HC MV (n = 5) with an 8.0 mm diameter endotracheal tube (ETT), locating...
متن کاملAerosol therapy: assume nothing and require data.
In this issue of RESPIRATORY CARE, Mitchell et al1 report a study in which they used a model of mechanical ventilation to examine differences in drug delivery between the hydrofluoroalkane (HFA) and chlorofluorocarbon (CFC) metered-dose inhaler (MDI) formulations of beclomethasone dipropionate (BDP). They discovered that the total emitted mass of drug at the end of the endotracheal tube (ETT) w...
متن کاملReconciling in vitro and in vivo measurements of aerosol delivery from a metered-dose inhaler during mechanical ventilation and defining efficiency-enhancing factors.
We attempted to resolve the discrepancies in reported data on aerosol deposition from a chlorofluorocarbon (CFC)-propelled metered-dose inhaler (MDI) during mechanical ventilation, obtained by in vivo and in vitro methodologies. Albuterol delivery to the lower respiratory tract was decreased in a humidified versus a dry circuit (16.2 versus 30.4%, respectively; p < 0.01). In 10 mechanically ven...
متن کاملHydrofluoroalkane-beclomethasone versus chlorofluorocarbon-beclomethasone delivery in neonatal models.
Dose delivery of hydrofluoroalkane-beclomethasone and chlorofluorocarbon-beclomethasone was compared during in vitro neonatal simulations: mechanical ventilation with 40% and 100% relative humidity + Neonatal Chamber-Ventilator System/endotracheal tube; manual ventilation + Neonatal Chamber/endotracheal tube; "spontaneous breathing" + Neonatal Chamber/face mask without/with manual assistance. T...
متن کاملImproved airway targeting with the CFC-free HFA-beclomethasone metered-dose inhaler compared with CFC-beclomethasone.
Hydrofluoroalkane-134a (HFA) beclomethasone dipropionate (BDP) was formulated in a metered-dose inhaler (MDI) to deliver a particle size of 1.1 microm compared with 35 microns for currently marketed chlorofluorocarbon (CFC)-BDP products. Two phase I single-dose human deposition studies were conducted using technetium 99m-radiolabelled BDP in a press-and-breathe actuator without an add-on spacer...