Statistical precision of the intensities retrieved from constrained fitting of overlapping peaks in high-resolution mass spectra

نویسندگان

  • M. J. Cubison
  • J. L. Jimenez
چکیده

Least-squares fitting of overlapping peaks is often needed to separately quantify ions in high-resolution mass spectrometer data. A statistical simulation approach is used to assess the statistical precision of the retrieved peak intensities. The sensitivity of the fitted peak intensities to statistical noise due to ion counting is probed for synthetic data systems consisting of two overlapping ion peaks whose positions are pre-defined and fixed in the fitting procedure. The fitted intensities are sensitive to imperfections in the m/Q calibration. These propagate as a limiting precision in the fitted intensities that may greatly exceed the precision arising from counting statistics. The precision on the fitted peak intensity falls into one of three regimes. In the “countinglimited regime” (regime I), above a peak separation χ ∼ 2 to 3 half-widths at half-maximum (HWHM), the intensity precision is similar to that due to counting error for an isolated ion. For smaller χ and higher ion counts (∼ 1000 and higher), the intensity precision rapidly degrades as the peak separation is reduced (“calibration-limited regime”, regime II). Alternatively for χ < 1.6 but lower ion counts (e.g. 10–100) the intensity precision is dominated by the additional ion count noise from the overlapping ion and is not affected by the imprecision in them/Q calibration (“overlapping-limited regime”, regime III). The transition between the counting and m/Q calibration-limited regimes is shown to be weakly dependent on resolving power and data spacing and can thus be approximated by a simple parameterisation based only on peak intensity ratios and separation. A simple equation can be used to find potentially problematic ion pairs when evaluating results from fitted spectra containing many ions. Longer integration times can improve the precision in regimes I and III, but a given ion pair can only be moved out of regime II through increased spectrometer resolving power. Studies presenting data obtained from least-squares fitting procedures applied to mass spectral peaks should explicitly consider these limits on statistical precision.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Signal detection in high-resolution mass spectrometry data.

Mass spectrometry data from high-resolution time-of-flight instruments often contain a vast number of noninformative background-ion peaks whose signal is similar to that of peptide peaks. Consequently, seeking peptide signal in these spectra based on a signal-to-noise ratio will remove signal peaks as well as noise. This work characterizes the background as a precursor to seeking peptide-relate...

متن کامل

Peak-fitting and integration imprecision in the Aerodyne aerosol mass spectrometer: effects of mass accuracy on location-constrained fits Citation

The errors inherent in the fitting and integration of the pseudo-Gaussian ion peaks in Aerodyne high-resolution aerosol mass spectrometers (HR-AMSs) have not been previously addressed as a source of imprecision for these or similar instruments. This manuscript evaluates the significance of this imprecision and proposes a method for their estimation in routine data analysis. In the first part of...

متن کامل

Benefits of Improved Resolution for Edxrf

The accuracy and precision of energy dispersive X-ray fluorescence (EDXRF) improve with improved detector energy resolution. However, there are trade-offs between the highest energy resolution and the highest count rates, and there are practical difficulties in achieving the very best energy resolution. Energy resolution differentiates systems but the benefits of improved energy resolution, in ...

متن کامل

Optimal analysis of complex protein mass spectra.

Due to physical and chemical phenomena, a simple sample can give rise to a complex mass spectrum with many more peaks than the number of molecular species present in the sample. We link peaks within and between different spectra, and come up with an advanced analysis approach to produce reliable estimates of the molecule masses and abundances. By linking peaks, we can locate multiple-charge pea...

متن کامل

Sub-pixel Precision Image Matching for Displacement Measurement of Mass Movements Using Normalised Cross-correlation

This study evaluates the performance of two fundamentally different approaches to achieve sub-pixel precision of normalised crosscorrelation when measuring surface displacements on mass movements from repeat optical images. In the first approach, image intensities are interpolated to a desired sub-pixel resolution using a bi-cubic interpolation scheme prior to the actual displacement matching. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015