Mapping and ablation of epicardial idiopathic ventricular arrhythmias from within the coronary venous system.
نویسندگان
چکیده
BACKGROUND The prevalence of epicardial idiopathic ventricular arrhythmias that can be ablated from within the coronary venous system (CVS) has not been described. METHODS AND RESULTS In a consecutive group of 189 patients with idiopathic ventricular arrhythmias referred for ablation, the site of origin (SOO) of ventricular tachycardia and/or premature ventricular contractions was determined by activation mapping and pace mapping. Mapping was performed within the CVS if endocardial mapping did not reveal an SOO. Venography of the CVS and coronary angiography were performed before ablation in the CVS. In 27 of 189 patients (14%+/-5%; 95% confidence interval), the SOO of the ventricular arrhythmia was identified from within the coronary venous system, either in the great cardiac vein (n=26) or the middle cardiac vein (n=1). The mean activation time at the SOO was -29+/-8 ms. Twenty of 27 patients (74%) underwent successful ablation within the CVS. Epicardial ventricular arrhythmias displayed a broader R wave in V(1) compared with arrhythmias in the control group (85 ms [interquartile range, 40] versus 65 ms [interquartile range, 95]; P<0.01). Two patients had recurrent premature ventricular contractions within 2 weeks after ablation, and no recurrences occurred in the remaining patients during a median follow-up of 13 months (range, 25). In the 7 patients with unsuccessful ablation, failure was because the ablation catheter could not be advanced to the SOO within the great cardiac vein (n=4), inadequate power delivery at the SOO (n=1), proximity to the phrenic nerve (n=1), or proximity of the SOO to a major coronary artery (n=1). Transcutaneous epicardial ablation was effective in 1 of 2 patients in whom it was attempted. CONCLUSIONS Almost 15% of idiopathic ventricular arrhythmias have an epicardial origin. ECG characteristics help to differentiate epicardial arrhythmias from endocardial ventricular arrhythmias. The SOO of epicardial arrhythmias can be ablated from within the CVS in approximately 70% of patients.
منابع مشابه
Percutaneous epicardial ablation of ventricular arrhythmias arising from the left ventricular summit: outcomes and electrocardiogram correlates of success.
BACKGROUND Percutaneous epicardial ablation of ventricular arrhythmias arising from the left ventricular summit is limited by the presence of major coronary vessels and epicardial fat. We report the outcomes of percutaneous epicardial mapping and ablation of ventricular arrhythmias arising from the left ventricular summit and the ECG features associated with successful ablation. METHODS AND R...
متن کاملConjunction of Endocardial and Coronary Venous System Mapping to Ablate Ventricular Arrhythmias.
BACKGROUND Ablation of idiopathic ventricular arrhythmias (VAs) with epicardial or intramural origins is technically challenging. Herein, we have described the successful ablation of left VAs via the coronary venous system (CVS) in conjunction with endocardial map guided by three-dimensional electroanatomical map in six patients. METHODS Out of a total consecutive 84 patients with symptomatic...
متن کاملAnatomic relationships between the coronary venous system, surrounding structures, and the site of origin of epicardial ventricular arrhythmias.
BACKGROUND Epicardial left ventricular (LV) idiopathic ventricular arrhythmias (VAs) can be approached via the pericardial space, the coronary venous system (CVS), or other surrounding structures. The anatomic relationships between epicardial sites of origin (SOO) of VAs and surrounding anatomic structures have not been systematically described. METHODS AND RESULTS In 17 patients with idiopat...
متن کاملIdiopathic Epicardial Ventricular Arrhythmias: Diagnosis and Ablation Technique from the Aortic Sinus of Valsalva
Idiopathic outflow tract arrhythmias (ventricular tachycardias or symptomatic premature ventricular contractions; OT-VT/PVCs) can originate from the left ventricular (LV) epicardium (Epi-VT/PVCs), and radiofrequency (RF) energy applications from the aortic sinus of Valsalva can eliminate Epi-VT/PVCs in selected patients. Among the various ECG findings, the R-wave duration index and R/S amplitud...
متن کاملCatheter Ablation of Idiopathic Premature Ventricular Contractions and Ventricular Tachycardias Originating from the Vicinity of Endocardial and Epicardial Mitral Annulus
BACKGROUND Several previous reports have revealed that idiopathic ventricular arrhythmias (VAs), including premature ventricular contractions (PVCs) and ventricular tachycardias (IVTs), can originate from endocardial mitral annulus (ENDO MA). However, these data are limited to ENDO MA VAs, and little is known about the electrocardiographic (ECG) characteristics and the efficacy of radiofrequenc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 3 3 شماره
صفحات -
تاریخ انتشار 2010