Analysis of Leakage Current to Predict Insulator Flashover Using Artificial Neural Network

نویسنده

  • Ebenezer Jeyakumar
چکیده

Problem statement: The phenomenon of flashover in polluted insulators has been continued by the study of the characteristics of contaminating layers deposited on the surface of insulators in high voltage laboratories. In the literature, Experimental investigations have been carried out on a real insulator or a flat plate model of insulators under high voltage application. This study proposed the Equivalent insulator flat plate model for studying the flashover phenomena due to pollution under wet conditions even at low voltage. Laboratory based tests were carried out on the model under AC voltage at different pollution levels. Different concentrations of salt solution has been prepared using sodium chloride, Kaolin and distilled water representing the various contaminations. Leakage current during the experimental studies were measured for various polluted conditions. Approach: A new model of Vc = f (V, Iinitial, Iem, Iemax and Iσ) based on artificial neural network has been developed to predict flashover from the analysis of leakage current. The input variable to the artificial neural network are mean (Imean), Maximum(Imax) and standard deviation(Iσ) of leakage current extracted along with the initial value of leakage current Iinitial and the input voltage(V).The target obtained was used to evaluate the performance of the neural network model. Results: The optimum process has been carried out based on the training accuracy measured by RMSE, the network converged to a threshold of 0.0001.The trained model prediction is in good agreement with the actual results and the R value of the developed model is 0.99996. Conclusion: The developed ANN model is well-suited for the analysis of leakage current to predict flashover on the insulator surface with high accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)

Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...

متن کامل

Investigation of Leakage Current of Insulator Using Artificial Neural Network

DOI: 10.5281/zenodo.60115 ABSTRACT In order to improve the reliability of power transmission lines, one of the key issues is to reduce the hazard of contamination flashovers. At the present time, the most efficient way is to clean (or replace) the heavily polluted insulators. This study laboratory based tests were carried out on the model under ac voltage at different pollution levels. A new mo...

متن کامل

Designation of an Indicator for flashover prediction of porcelain and glass insulators based on experimental tests.

Flashover of polluted insulators in contaminated areas is one of the most important factors influencing the operation of transmission and distribution lines and finally line outages. Therefore, it is essential to prevent and detect flashover in the insulators. Hence, utilizing the insulator status monitoring systems and predicting their functions have absorbed a lot of attention over the recent...

متن کامل

Electric Transmission Line Flashover Prediction System

This is a project report from the Power Systems Engineering Research Center (PSERC). PSERC is a multi-university Center conducting research on challenges facing a restructuring electric power industry and educating the next generation of power engineers. More information about PSERC can be found at the Center's website: and major advisor in the preparation of the thesis. We express our apprecia...

متن کامل

Modeling Ac Arc Re-ignition Conditions on Ice -covered Insulators Using Artificial Neural Networks

The propagation of local arcs are necessary for a flashover to occur on an ice-covered insulator. It was supposed that the local AC arc extended when it satisfied the arc re-ignition conditions. In this paper an attempt has been made to model Va = f ( I , L , x ) for estimating the arc re-ignition conditions as function of leakage current and insulator length using multi-layer feed-forward neur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011