Comparison of Markerless and Marker-Based Motion Capture Technologies through Simultaneous Data Collection during Gait: Proof of Concept
نویسندگان
چکیده
During the last decade markerless motion capture techniques have gained an increasing interest in the biomechanics community. In the clinical field, however, the application of markerless techniques is still debated. This is mainly due to a limited number of papers dedicated to the comparison with the state of the art of marker based motion capture, in term of repeatability of the three dimensional joints' kinematics. In the present work the application of markerless technique to data acquired with a marker-based system was investigated. All videos and external data were recorded with the same motion capture system and included the possibility to use markerless and marker-based methods simultaneously. Three dimensional markerless joint kinematics was estimated and compared with the one determined with traditional marker based systems, through the evaluation of root mean square distance between joint rotations. In order to compare the performance of markerless and marker-based systems in terms of clinically relevant joint angles estimation, the same anatomical frames of reference were defined for both systems. Differences in calibration and synchronization of the cameras were excluded by applying the same wand calibration and lens distortion correction to both techniques. Best results were achieved for knee flexion-extension angle, with an average root mean square distance of 11.75 deg, corresponding to 18.35% of the range of motion. Sagittal plane kinematics was estimated better than on the other planes also for hip and ankle (root mean square distance of 17.62 deg e.g. 44.66%, and 7.17 deg e.g. 33.12%), meanwhile estimates for hip joint were the most incorrect. This technique enables users of markerless technology to compare differences with marker-based in order to define the degree of applicability of markerless technique.
منابع مشابه
Comparison of lower limb and trunk kinematics between markerless and marker-based motion capture systems.
Three dimensional (3-D) motion capture systems are used by researchers and clinicians to analyze the kinematics of human movement. Traditional marker based systems are time consuming and limit the size of studies. Markerless 3-D systems are quicker to use but the differences between data captured in each system is unclear. AIM To examine the relationship of kinematic data captured by marker b...
متن کاملFeasibility of a single camera markerless motion capture system to accurately measure flexion-extension
INTRODUCTION Traditional motion capture techniques use markers to measure movement. However, markers are prone to soft tissue artifact and experimental error [1] as well as possible impedance to natural motion. Another significant challenge is the ability to use optical motion capture systems in a variety of natural setting such as a patient’s home, on the sports field, or in public. This has l...
متن کاملMarkerless Human Motion Capture for Gait Analysis
The aim of our study is to detect balance disorders and a tendency towards the falls in the elderly, knowing gait parameters. In this paper we present a new tool for gait analysis based on markerless human motion capture, from camera feeds. The system introduced here, recovers the 3D positions of several key points of the human body while walking. Foreground segmentation, an articulated body mo...
متن کاملApplications of markerless motion capture in gait recognition.
This thesis is based on four manuscripts where two of them were accepted and two were submitted to peer-reviewed journals. The experimental work behind the thesis was conducted at the Institute of Neuroscience and Pharmacology, University of Copenhagen. The purpose of the studies was to explore the variability of human gait and to conduct new methods for precise estimation of the kinematic para...
متن کاملMarkerless Motion Capture within Sport: an Exploratory Case Study
The purpose of this case study was to compare centre of mass (CoM) recorded by a markerless motion capture system (60 Hz) to a criterion marker based system (120 Hz). Gait kinematics of one healthy male participant was recorded five times by both capture systems simultaneously. CoM position was assessed using a full body six degrees of freedom model, normalised to the stance phase based on a 20...