INTRODUCTION Optic nerve sheath diameter (ONSD) measurement with bedside ultrasound has been shown in many studies to accurately detect high intracranial pressure (ICP). The accuracy of point-in-time ONSD measurement in the presence of ongoing fluctuation of ICP between high and normal is not known. Recent laboratory investigation suggests that reversal of optic nerve sheath distension may be impaired following bouts of intracranial hypertension. Our objective was to compare the accuracy of ONSD measurement in the setting of fluctuating versus stable ICP. METHODS This was a retrospective analysis of data from prospective study comparing ONSD to invasive ICP. Patients with invasive ICP monitors in the ICU underwent ONSD measurement with simultaneous blinded recording of ICP from the invasive monitor. Three measurements were made in each eye. Significant acute ICP fluctuation (SAIF) was defined in two different ways; as the presence of ICP both above and below 20 mmHg within a cluster of six measurements (Definition 1) and as a magnitude of fluctuation >10 mmHg within the cluster (Definition 2). The accuracy of point-in-time ONSD measurements for the detection of concurrent ICP >20 mmHg within clusters fulfilling a specific definition of SAIF was compared to the accuracy of ONSD measurements within clusters not fulfilling the particular definition by comparison of independent receiver operating characteristic (ROC) curves. RESULTS A total of 613 concurrent ONSD-ICP measurements in 109 clusters were made in 73 patients. Twenty-three (21%) clusters fulfilled SAIF Definition 1 and 17 (16%) SAIF Definition 2. For Definition 1, the difference in the area under the curve (AUC) of ROC curves for groups with and without fluctuation was 0.10 (P = 0.0001). There was a fall in the specificity from 98% (95% CI 96 to 99%) to 74% (63 to 83%) and in the positive predictive value from 89% (80 to 95%) to 76% (66 to 84%) with fluctuation. For Definition 2, also, there was a significant difference between the AUC of ROC curves of groups with fluctuation-magnitude >10 mmHg and those with fluctuation-magnitude 5 to 10 mmHg (0.06, P = 0.04) as well as <5 mmHg (0.07, P = 0.01). CONCLUSIONS Specificity and PPV of ONSD for ICP >20 mmHg are substantially decreased in patients demonstrating acute fluctuation of ICP between high and normal. This may be because of delayed reversal of nerve sheath distension.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scuba-diving on optic nerve and sheath diameters

  Background :There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated.   Methods : Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one perso...

متن کامل

Prospective Analysis of Single Operator Sonographic Optic Nerve Sheath Diameter Measurement for Diagnosis of Elevated Intracranial Pressure

INTRODUCTION The accurate diagnosis of elevated intracranial pressure (eICP) in the emergent setting is a critical determination that presents significant challenges. Several studies show correlation of sonographic optic nerve sheath diameter (ONSD) to eICP, while others show high inter-observer variability or marginal performance with less experienced sonographers. The objective of our study i...

متن کامل

Optic Nerve Sheath Ultrasound for the Bedside Diagnosis of Intracranial Hypertension: Pitfalls and Potential

Raised intracranial pressure is a complication not just of traumatic brain injury and other acute cerebral insults, but also of a number of general medical conditions. Bedside diagnosis can be difficult; early clinical signs may be misinterpreted, and reliance on cross-sectional imaging studies may further delay diagnosis. Ultrasound is a readily available imaging modality in most critical care...

متن کامل

Optic nerve ultrasound for the detection of raised intracranial pressure.

BACKGROUND Optic nerve ultrasonography (ONUS) may help identify raised intracranial pressure (ICP). The optimal optic nerve sheath diameter (ONSD) cut-off for the identification of intracranial hypertension has not been established, with some clinical studies suggesting a higher cut-off than may be expected on the basis of prior laboratory investigation. OBJECTIVE To validate ONUS performed b...

متن کامل

Pulsatile Dynamics of the Optic Nerve Sheath and Intracranial Pressure: An Exploratory In Vivo Investigation

BACKGROUND Raised intracranial pressure (ICP) may lead to increased stiffness of the optic nerve sheath (ONS). OBJECTIVE To develop a method for analyzing ONS dynamics from transorbital ultrasound and investigate a potential difference between patients with raised ICP vs normal ICP. METHODS We retrospectively analyzed data from 16 patients (≤12 years old) for whom ultrasound image sequences...