Clinical and angiographic predictors of restenosis after stent deployment in diabetic patients.
نویسندگان
چکیده
BACKGROUND Restenosis and consequent adverse cardiac events are increased in diabetics undergoing percutaneous coronary intervention. Use of intracoronary stents may ameliorate such risks; however, factors influencing the likelihood of restenosis after stent deployment in this high-risk patient subgroup are unknown. METHODS AND RESULTS We retrospectively analyzed all stented diabetic patients in 16 studies of percutaneous coronary intervention, all of which underwent core angiographic analysis at Cardialysis, Rotterdam. Univariate and multivariate analyses, with 37 clinical and angiographic variables, compared those with and without restenosis and predicted restenosis rates calculated through the use of reference charts derived from angiographic data. Within the studies, 418 of 3090 (14%) stented patients with 6-month angiographic follow-up had diabetes. Restenosis (> or =50% diameter stenosis at follow-up) occurred in 550 of 2672 (20.6%) nondiabetic and 130 of 418 (31.1%) diabetic patients (P<0.001). Univariate predictors of restenosis in diabetics were smaller vessel reference diameter (RD) (P<0.001), smaller minimal luminal diameter before stenting (P=0.01), smaller minimal luminal diameter and percent diameter stenosis after stenting (P<0.001, P=0.04), greater stented length of vessel (P<0.001), and reduced body mass index (BMI) (P=0.04). With the use of multivariate analysis, only smaller RD (P=0.003), greater stented length of vessel (P=0.04), and reduced BMI (P=0.04) were associated with restenosis. Reference charts demonstrated an incremental risk of restenosis that appears solely dependent on vessel RD. CONCLUSIONS Restenosis after stent deployment is significantly increased in diabetic patients. Vessel caliber, stented length of vessel, and lower BMI are predictors of in-stent restenosis in patients with diabetes. Furthermore, vessel caliber affected the predicted risk of restenosis incrementally.
منابع مشابه
Safety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملIntravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation.
AIMS In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-mon...
متن کاملعوامل پیشگوییکننده انسداد شاخه جانبی و عوارض زودرس آن به دنبال آنژیوپلاستی عروق کرونر
Background: Percutaneous Coronary Intervention (PCI) for bifurcated lesions is associated with a low rate of success and high rate of complications compared to such treatment of lesions of most other morphologies. Symptoms occurring at the time of procedure caused by PCI may require additional angiography with or without stenting through stent struts, which subsequently increases risks of reste...
متن کاملRandomized comparison of cilostazol vs clopidogrel after drug-eluting stenting in diabetic patients--clilostazol for diabetic patients in drug-eluting stent (CIDES) trial.
BACKGROUND Previous studies have shown that cilostazol may not only prevent stent thrombosis, but may also have positive effect in the prevention of restenosis. However, the effect of cilostazol on restenosis after successful deployment of drug-eluting stent (DES) in patients with diabetes mellitus has not been evaluated. METHODS AND RESULTS A total of 280 patients at 8 clinical sites were ra...
متن کاملAngiographic and intravascular ultrasound predictors of in-stent restenosis.
OBJECTIVES This study was performed to determine predictors of in-stent restenosis from a high volume, single-center practice. BACKGROUND Intracoronary stents have been shown to reduce the restenosis rate as compared with balloon angioplasty, but in-stent restenosis continues to be an important clinical problem. METHODS Between April 1993 and March 1997, 1,706 patients with 2,343 lesions we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 109 7 شماره
صفحات -
تاریخ انتشار 2004