A microfluidic anti-Factor Xa assay device for point of care monitoring of anticoagulation therapy.

نویسندگان

  • Leanne F Harris
  • Paul Rainey
  • Vanessa Castro-López
  • James S O'Donnell
  • Anthony J Killard
چکیده

The development of new point of care coagulation assay devices is necessary due to the increasing number of patients requiring long-term anticoagulation in addition to the desire for appropriate, targeted anticoagulant therapy and a more rapid response to optimization of treatment. The majority of point of care devices currently available for hemostasis testing rely on clot-based endpoints which are variable, unreliable and limited to measuring only certain portions of the coagulation pathway. Here we present a novel fluorescence-based anti-Factor Xa (FXa) microfluidic assay device for monitoring the effect of anticoagulant therapy at the point of care. The device is a disposable, laminated polymer microfluidic strip fabricated from a combination of hydrophobic and hydrophilic cyclic polyolefins to allow reagent deposition in addition to effective capillary fill. Zeonor was the polymer of choice resulting in low background fluorescence (208.5 AU), suitable contact angles (17.5°± 0.9°) and capillary fill times (20.3 ± 2.1 s). The device was capable of measuring unfractionated heparin and tinzaparin from 0-0.8 U ml(-1) and enoxaparin from 0-0.6 U ml(-1) with average CVs < 10%. A linear correlation was observed between the device and the fluorescent assay in the plate for plasma samples spiked with UFH, with an R(2) value of 0.99, while correlations with tinzaparin and enoxaparin resulted in sigmoidal responses (R(2) = 0.99). Plasma samples containing UFH resulted in a linear correlation between the device and a standard chromogenic assay with an R(2) value of 0.98, with both LMWHs resulting in sigmoidal relationships (R(2) = 0.99).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Utility and correlation of known anticoagulation parameters in the management of pediatric ventricular assist devices

AIM To assess utility and correlation of known anticoagulation parameters in the management of pediatric ventricular assist device (VAD). METHODS Retrospective study of pediatric patients supported with a Berlin EXCOR VAD at a single pediatric tertiary care center during a single year. RESULTS We demonstrated associations between activated thromboplastin time (aPTT) and R-thromboelastograph...

متن کامل

Bedside monitoring of anticoagulation in chronic haemodialysis patients treated with tinzaparin.

BACKGROUND During haemodialysis, anticoagulants are required to prevent clotting in the extracorporeal circuit. Low-molecular weight heparins (LMWH) are frequently used because of the ease of a single injection at the start of dialysis. Disadvantages of LMWH include the lack of a reliable bedside assay for measuring their anticoagulant effect. METHODS We investigated a bedside test for LMWH a...

متن کامل

Activated partial thromboplastin time versus antifactor Xa heparin assay in monitoring unfractionated heparin by continuous intravenous infusion.

BACKGROUND Unfractionated heparin (UFH) has been used clinically for 5 decades. Despite being a cornerstone of anticoagulation, UFH is limited by its unpredictable pharmacokinetic profile, which makes close laboratory monitoring necessary. The most common methods for monitoring UFH are the activated partial thromboplastin time (aPTT) and antifactor Xa heparin assay (anti-Xa HA), but both presen...

متن کامل

Anti-factor Xa and activated partial thromboplastin time measurements for heparin monitoring in mechanical circulatory support.

OBJECTIVES This study investigated the relationship between anti-factor Xa (anti-FXa) and activated partial thromboplastin time (aPTT) for monitoring intravenous unfractionated heparin (IV-UFH) in patients with continuous-flow left ventricular assist devices (CF-LVADs). BACKGROUND CF-LVADs have become mainstream therapy for patients with advanced heart failure. Thromboembolic events, device t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 138 17  شماره 

صفحات  -

تاریخ انتشار 2013