The Impact of Heat Treatment on Porcine Heart Valve Leaflets
نویسندگان
چکیده
The purpose of this study was to determine the impact of elevated temperature exposure in tissue banking on soft tissues. A secondary objective was to determine the relative ability of various assays to detect changes in soft tissues due to temperature deviations. Porcine pulmonary heart valve leaflets exposed to 37 °C were compared with those incubated at 52 and 67 °C for 10, 30 and 100 min. The analytical methods consisted of (1) viability assessment using the resazurin assay, (2) collagen content using the Sircol assay, and (3) permeability assessment using an electrical conductivity assay. Additionally, histology and two photon microscopy were used to reveal mechanisms of cell and tissue damage. Viability, collagen content, and permeability all decreased following heat treatment. In terms of statistical significance with respect to treatment temperature, cell viability was most affected (p < 0.0001), followed by permeability (p < 0.0001), and then collagen content (p = 0.13). After heat treatment, histology indicated increased apoptosis and two photon microscopy revealed a decrease in collagen fiber organization and an increase in elastin density. These results suggest that measures of cell viability would be best for assessing tissues where the cells are alive and that permeability may be best where cell viability is not intentionally maintained.
منابع مشابه
گزارش 3 بیمار مبتلا به تونل آئورت به بطن چپ
Aorto-left ventricular tunnel (ALVT) is a rare congenital anomaly in which an abnormal communication connects the ascending aorta with the left ventricle, that results volume overload on left ventricle. It is clinically undistinguishable from aortic insufficiency. Its prompt and precise diagnosis is crucial since early surgical treatment is definitely indicated. In this report clinical,...
متن کاملCalcification of Porcine Aortic Valvular Interstitial Cells
Calcific aortic stenosis (AS), stiffening of aortic valve leaflets and narrowing of the aortic orifice, is the most common heart valve disease in developed countries [1]. The aortic valve is located between the aorta and the left ventricle and consists of 3 leaflets. Each leaflet contains outer endothelial layers and interstitial cells interspersed in the matrix between the endothelial layers. ...
متن کاملPlanar biaxial behavior of fibrin-based tissue-engineered heart valve leaflets.
To design more effective tissue-engineered heart valve replacements, the replacement tissue may need to mimic the biaxial stress-strain behavior of native heart valve tissue. This study characterized the planar biaxial properties of tissue-engineered valve leaflets and native aortic valve leaflets. Fibrin-based valve equivalent (VE) and porcine aortic valve (PAV) leaflets were subjected to incr...
متن کاملAge-Related Changes in Mechanical Properties in Porcine Heart Valves
Mechanical and bioprosthetic valves work relatively well in adults, but have complications in children. Even if the complications could be resolved, neither of these valve replacements can grow with the child, which a tissue engineered heart valve (TEHV) is expected to do. Recent studies in valve structure and composition showed significant agerelated changes. This indicates that there are like...
متن کاملComprehensive Analysis on the Effect of Deep Cryogenic Treatment on The Mechanical Behaviour of Martensitic Valve steel
The behaviour of the cryogenically treated En52 martensitic valve steel has been experimentally analyzed in this paper. Material samples are subjected to deep cryogenic treatment after completing the regular heat treatment. The critical properties of the valve steel like wear resistance, hardness, tensile strength and impact strength are evaluated for the cryo treated En52 valve steel samples a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2018