Dose reduction in paediatric MDCT: general principles.
نویسندگان
چکیده
The number of multi-detector array computed tomography (MDCT) examinations performed per annum continues to increase in both the adult and paediatric populations. Estimates from 2003 suggested that CT contributed 17% of a radiology department's workload, yet was responsible for up to 75% of the collective population dose from medical radiation. The effective doses for some CT examinations today overlap with those argued to have an increased risk of cancer. This is especially pertinent for paediatric CT, as children are more radiosensitive than adults (and girls more radiosensitive than boys). In addition, children have a longer life ahead of them, in which radiation induced cancers may become manifest. Radiologists must be aware of these facts and practise the ALARA (as low as is reasonably achievable) principle, when it comes to deciding CT protocols and parameters.
منابع مشابه
Radiation exposure in computed tomography: comparison of adult and paediatrics radiology practice in Serbia
There are 90 CT units operating in Serbia, with tenfold increase in the last decade, resulting with annual total of approximately 350000 procedures. The objective of this paper is to assess typical patient dose from adult and paediatric CT examinations. Initially, three hospitals (two general hospitals performing examination of adults and a dedicated paediatric hospital) were enrolled into the ...
متن کاملPaediatric multi-detector row chest CT: what you really need to know
BACKGROUND The emergence of multi-detector row CT (MDCT) has established and extended the role of CT especially in paediatric chest imaging. This has altered the way in which data is acquired and is perceived as the 'gold standard' in the detection of certain chest pathologies. The range of available post-processing tools provide alternative ways in which CT images can be manipulated for review...
متن کاملApplication of Different methods for Reducing Radiation Dose to Breast during MDCT
The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...
متن کاملCone beam CT for dental and maxillofacial imaging: dose matters.
The widespread use of cone-beam CT (CBCT) in dentistry has led to increasing concern regarding justification and optimisation of CBCT exposures. When used as a substitute to multidetector CT (MDCT), CBCT can lead to significant dose reduction; however, low-dose protocols of current-generation MDCTs show that there is an overlap between CBCT and MDCT doses. More importantly, although the 3D info...
متن کاملNon-coronary findings in cardiac CT
Gated multi-detector CT (MDCT) is now recognised as an excellent and robust application for non-invasive assessment of coronary arteries, and in many centres is routinely used. Some studies have shown that MDCT scanners with 64-detector row have a 99% negative predictive value for the detection of coronary artery stenosis. MDCT images obtained with ECG gating are superior to the standard (non-E...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical radiology
دوره 62 6 شماره
صفحات -
تاریخ انتشار 2007