Laboratory contamination of blood cultures.

نویسندگان

  • R C Spencer
  • M A Savage
چکیده

A prospective study of the use of a laminar flow cabinet, an exhaust-ventilated safety hood, and the open bench for the microbiological examination of blood is described. Blood samples from 1600 patients were subcultured on the open bench, 2700 in a safety hood, and 2607 in a laminar flow cabinet. Use of the laminar flow cabinet produced a significantly greater level of contamination than the other methods, and it is concluded that the exhaust-ventilated safety hood should be used for this procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

آلودگی باکتریال کشت‌های خون مرکز طبی کودکان تهران - فروردین تا خرداد 1383

Background: Blood culture is the criterion standard for identifying children with bacteremia. However, elevated false-positive rates are common and are associated with substantial health care costs. The aims of this prospective study were to: 1) determine the rate of blood culture contamination 2) determine variety and frequency of contaminant bacteria 3) compare the duration of hospital stay a...

متن کامل

Cross contamination of blood cultures associated with a multiple use venting device.

AIM To investigate cross contamination of blood cultures associated with multiple use venting devices, which are widely used in clinical microbiology laboratories to reduce labour costs. METHODS Systematic analysis of 13,880 blood culture results in a large teaching hospital where multiple use venting devices were employed. RESULTS Nine series of potential cross contamination were identifie...

متن کامل

Contamination of cultures processed with the isolator lysis-centrifugation blood culture tube.

Overall contamination (on- plus off-streak) of the Isolator (Du Pont Co.) blood culture tube (23%) was greater than that of a conventional broth blood culture bottle (0.6%) or that of a biphasic blood culture bottle (1.3%). To determine the source of this contamination, Isolator cultures of blood from 59 healthy volunteers and of sterile broth from 60 vials were made. A total of 37% of the bloo...

متن کامل

Contamination of Blood Cultures 1055

Contamination of blood cultures is believed to occur mainly during the venepuncture procedure. Consequently, meticulous preparation of the venepuncture site is widely recommended. To determine whether the contamination rate is indeed affected by the quality of the antiseptic procedure at the venepuncture site, 181 paired cultures were collected from 176 patients during a 6-month period after ei...

متن کامل

Reducing blood culture contamination by a simple informational intervention.

Compared to truly negative cultures, false-positive blood cultures not only increase laboratory work but also prolong lengths of patient stay and use of broad-spectrum antibiotics, both of which are likely to increase antibiotic resistance and patient morbidity. The increased patient suffering and surplus costs caused by blood culture contamination motivate substantial measures to decrease the ...

متن کامل

Blood culture contamination in hospitalized pediatric patients: a single institution experience

PURPOSE Blood culture is the most important tool for detecting bacteremia in children with fever. However, blood culture contamination rates range from 0.6% to 6.0% in adults; rates for young children have been considered higher than these, although data are limited, especially in Korea. This study determined the contamination rate and risk factors in pediatric patients visiting the emergency r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 28 12  شماره 

صفحات  -

تاریخ انتشار 1975