Two in vivo surgical approaches for lumbar corpectomy using allograft and a metallic implant: a controlled clinical and biomechanical study.

نویسندگان

  • Philbert Huang
  • Munish C Gupta
  • Nesrin Sarigul-Klijn
  • Scott Hazelwood
چکیده

BACKGROUND CONTEXT Both bone graft and metallic implants have been used in combination with the necessary anterior rod or plate instrumentation to fill the voids left by vertebral body removal, with the ultimate goal of restoring stability. One type of device that has recently been introduced is an expandable titanium telescoping cage that is designed to be used as a strut implant to fill corpectomy defects. The use of these devices has met varying success. Acceptance by surgeons and spine biomechanicians has been limited by clinical failure with subsequent loss of reduction and increase in kyphosis. In order to further improve patient care, it is critical to evaluate the use of these implants through biomechanical as well as other modes of testing. PURPOSE To compare and contrast the spinal fusion outcome of using allograft bone versus the expandable vertebral body replacement titanium implant in a lumbar corpectomy procedure. STUDY DESIGN Controlled biomechanical study of lumbar spine fusion using bone graft and the expandable cage in an in vivo bovine model after a 4-month postoperative healing period (n=6). ANIMAL MODEL: Twelve Holstein calves aged 4-6 months with L3 and adjacent discs removed to create a simulated lumbar corpectomy defect. OUTCOME MEASURES Lumbar spine stability after corpectomy repair was quantified by biomechanical parameters. Strength of fusion was assessed by stiffness of ex vivo spine specimens in flexion-extension, lateral bending, and torsion obtained from biomechanical testing. Uniaxial strain at various positions on the surface of the anterior plate was measured during loading as an additional stability parameter. Loading tests were repeated after removal of the anterior instrumentation (plate and the screws). METHODS The calves were randomly allocated to groups for corpectomy defect repair with 1) Allograft metatarsal bone and thoracolumbar spine locking plate, n=6; or 2) Expandable vertebral body replacement device, and thoracolumbar spine locking plate, n=6. After a 4-month postoperative period, anterior-posterior and lateral radiographs were taken of the spine, followed by animal sacrifice and harvesting of the lumbar spine for biomechanical and histological testing. For biomechanical testing, uniaxial strain gauges were applied to the thoracolumbar spine locking plate to measure plate deformation during loading in a custom built fixture for application of flexion-extension, lateral bending, and torsion moments in an Instron materials testing machine. These loading tests were repeated with the thoracolumbar spine locking plate removed, thereby loading solely the fused segment. RESULTS At 4 months postoperative, the stiffness of the calf spines repaired by the metatarsal allograft and thoracolumbar spine locking plate was significantly greater than that of the spines repaired by the expandable cage and thoracolumbar spine locking plate. This finding was true for all three directions of loading (flexion-extension, left-right lateral bending, and torsion). Concordantly, the neutral zone, elastic zone, and range of motion of the spines repaired with the allograft bone were less than that of the spines repaired with the expandable cage. Greater strain values were observed from the gauges on the thoracolumbar spine locking plate of the spines using the expandable cage than the spines using allograft bone. This finding held for all gauge positions (anterior edge, anterior face, posterior edge, and posterior face at the longitudinal midpoint of the plate). After thoracolumbar spine locking plate removal and a repeat of the loading tests, a decrease in stiffness of the construct and a rise in the motion parameters were observed for both the allograft and cage groups. CONCLUSIONS The use of allograft bone for corpectomy defect repair in the lumbar spine appears to contribute to a stiffer and perhaps more stable spine segment compared with using the expandable cage device for such a repair after a 4-month healing period in this in vivo calf model. These findings thus far are based upon the biomechanical data gathered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical, Histologic and Histomorphometric Evaluation of Bone Strip Allograft with Resorbable Membrane in Horizontal Alveolar Ridge Augmentation: A Preliminary Study

  Objective: Alveolar ridge preservation in patients with inadequate bone volume is one treatment option for successful implant placement and can be done by using bone graft materials. On the other hand, Ceno Bone has been recently produced by Hamanand Saz Baft Kish Co. as a bone bioimplant of allograft origin. This study aimed to assess the clinical, histologic and histomorphometric results of...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Management of strut graft failure in anterior cervical spine surgery.

Although successfully used, long strut grafts are vulnerable to dislodgment, displacement, fracture, and nonunion, which can require revision surgery; thus, meticulous preparation of the vertebral endplate along with exact sizing and harvesting of the bone graft with plating are essential for successful outcomes. Biomechanical data and previous clinical studies support the addition of posterior...

متن کامل

The Anterior Retroperitoneal Approach to the Degenerative Lumbar Spine: Clinico-Therapeutic Remarks

The anterior approach is a well-known surgical technique for the treatment of degenerative diseases of the lumbar spine. Through this approach is possible to perform arthrodesis, arthroplasty, discectomy, corpectomy to treat a lot of degenerative conditions. The ALIF procedure is one of the most widely used technique, and is argued to have biomechanical advantages over posterior approaches for ...

متن کامل

Anterior Cervical Corpectomy Non-Fusion Model Produced by a Novel Implant.

BACKGROUND Anterior cervical corpectomy and fusion are frequently used in the treatment of cervical spinal disease. However, the range of motion (ROM) of the operative level is unavoidably lost due to fusion. This study aims to establish an anterior cervical corpectomy goat non-fusion model and to evaluate the ROM of adjacent and operative levels. MATERIAL/METHODS Six adult-male goats (in viv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 2006