Development of a candidate secondary reference procedure (immunoassay based measurement procedure of higher metrological order) for cardiac troponin I: I. Antibody characterization and preliminary validation.
نویسندگان
چکیده
In this study, the first steps in the development of a secondary reference measurement procedure (RMP) 'higher metrological order measurement procedure' to support the cardiac troponin I (cTnI) standardization initiative is described. The RMP should be used to assign values to serum-based secondary reference materials (RMs) without analytical artifacts causing bias. A multiplexed bead-based assay and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) were used to identify the optimum monoclonal antibody pair (clones 560 and 19C7) for the RMP. Using these antibodies, an ELISA-based procedure was developed to accurately measure the main cTnI forms present in blood. The proposed RMP appears to show no bias when tested on samples containing various troponin complexes, phosphorylated and dephosphorylated forms, and heparin. The candidate assay displayed suitable linearity and sensitivity (limit of detection, 0.052 μg/L) for the measurement of the proposed cTnI secondary RMs. Preliminary comparison data on patient samples with a commercial cTnI assay are also provided to support the suitability of RMP for value assignment to RMs. Full validation and final assessment of the RMP will be performed through transferability and inter-comparison studies.
منابع مشابه
Standardisation of cardiac troponin I measurement: past and present.
The laboratory measurement of cardiac troponin (cTn) concentration is a critical tool in the diagnosis of acute myocardial infarction (MI). Current cTnI assays produce different absolute troponin numbers and use different clinical cut-off values; hence cTnI values cannot be interchanged, with consequent confusion for clinicians. A recent Australian study compared patient results for seven cTnI ...
متن کاملValidation of Serum Cardiac Troponin I Reference Materials Using an Immunoprecipitation Method Coupled with Fluorescent Western Blot Analysis
Cardiac troponin I (cTnI) is adopted as the ‘gold standard’ cardiac biomarker following the universal definition of myocardial infarction (MI). Presently, the performance of commercial cTnI immunoassays varies significantly despite the recalibration using a troponin standard reference material, NIST SRM 2921. To standardize the cTnI immunoassays, a secondary reference material consisting of a p...
متن کاملFully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.
BACKGROUND The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay with very high sensitivity and outstanding analytical performance. We report...
متن کاملStandardization of troponin I measurements: an update.
Standardization of cardiac troponin I (cTnI) measurement is important because of the central role for diagnosis of myocardial infarction. In blood, cTnI is present as a heterogeneous mixture of different molecular species. The analytical problem caused by this heterogeneity may be circumvented by recognition of a unique, invariant part of the molecule that is common to all components of the mix...
متن کاملEvaluation of cardiac troponin I (cTnI), electrocardiography, creatine kinase (CK) and aspartate aminotransferase (AST) in diagnosis of selenium deficiency in Markhoz goat kids breed
BACKGROUND: Cardiac Troponin I (cTnI) is known as a cardiac biomarker in determining the myocardial damage of diseases which affect the heart muscle. OBJECTIVES: This study aims to evaluate the serum cTnI concentration in Markhoz Breed goats suffering selenium (Se) deficiency and its correlation with electrocardiographic parameters, and activity of creatine kinase (CK) and aspartate aminotransf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 48 11 شماره
صفحات -
تاریخ انتشار 2010