Comparative study of friction between metallic and conventional interactive self-ligating brackets in different alignment conditions

نویسندگان

  • Sérgio Ricardo Jakob
  • Davison Matheus
  • Maria Cristina Jimenez-Pellegrin
  • Cecília Pedroso Turssi
  • Flávia Lucisano Botelho do Amaral
چکیده

OBJECTIVE The aim of this study was to compare the friction between three bracket models: conventional stainless steel (Ovation, Dentsply GAC), self-ligating ceramic (In-Ovation, Denstply GAC) and self-ligating stainless steel brackets (In-Ovation R, Dentsply GAC). METHODS Five brackets were used for each model. They were bonded to an aluminum prototype that allowed the simulation of four misalignment situations (n = 10). Three of these situations occured at the initial phase (in which a 0.016-in nickel-titanium wire was used): 1. horizontal; 2. vertical; and 3. simultaneous horizontal/vertical. One of the situations occurred at the final treatment phase: 4. no misalignment (in which a 0.019 x 0.025-inch stainless steel rectangular wire was used). The wires slipped through the brackets and friction was measured by a Universal Testing Machine. RESULTS Analysis of variance followed by Tukey's Test for multiple comparisons (α = 0.05) were applied to assess the results. Significant interaction (p < 0.01) among groups was found. For the tests that simulated initial alignment, Ovation® bracket produced the highest friction. The two self-ligating models resulted in lower and similar values, except for the horizontal situation, in which In-Ovation C® showed lower friction, which was similar to the In-Ovation R® metallic model. For the no misalignment situation, the same results were observed. CONCLUSION The self-ligating system was superior to the conventional one due to producing less friction. With regard to the material used for manufacturing the brackets, the In-Ovation C® ceramic model showed less friction than the metallic ones.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resistance to Sliding in Clear and Metallic Damon 3 and Conventional Edgewise Brackets: an In vitro Study

STATEMENT OF THE PROBLEM Frictional forces are considered as important counterforce to orthodontic tooth movement. It is claimed that self-ligating brackets reduce the frictional forces. PURPOSE The aim of this study was to compare the resistance to sliding in metallic and clear Damon brackets with the conventional brackets in a wet condition. MATERIALS AND METHOD The samples included 4 typ...

متن کامل

Frictional resistance in self-ligating orthodontic brackets and conventionally ligated brackets. A systematic review.

OBJECTIVE To compare the amount of expressed frictional resistance between orthodontic self-ligating brackets and conventionally ligated brackets in vitro as reported in the literature. METHODS Several electronic databases (Medline, PubMed, Embase, Cochrane Library, and Web of Science) were searched without limits. In vitro studies that addressed friction of self-ligating brackets compared wi...

متن کامل

Frictional resistance of self-ligating versus conventional brackets in different bracket-archwire-angle combinations

OBJECTIVE To compare the influence of archwire material (NiTi, beta-Ti and stainless steel) and brackets design (self-ligating and conventional) on the frictional force resistance. MATERIAL AND METHODS Two types of brackets (self-ligating brackets - Smartclip, 3M/Unitek - and conventional brackets - Gemini, 3M/Unitek) with three (0, 5, and 10 degrees) slot angulation attached with elastomeric...

متن کامل

Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

AIM The aim of this study was to compare frictional resistance which was produced between conventional brackets (0.022 slot Otho-Organiser) and self ligating brackets (active Forestadent and passive Damon III) by using various arch wire combinations (0.016 Niti, 0.018 Niti, 0.017 x 0.025 SS and 0.019 x 0.025 SS). METHODS An experimental model which consisted of 5 aligned stainless steel 0.022...

متن کامل

Evaluation of the Friction of Self-Ligating and Conventional Bracket Systems

OBJECTIVES This in vitro study evaluated the friction (F) generated by aligned stainless steel (SS) conventional brackets, self-ligating Damon MX(©) brackets (SDS Ormco, Glendora, California, USA), Time3(©) brackets (American Orthodontics, Sheboygan, Wisconsin, USA), Vision LP(©) brackets (American Orthodontics), and low-friction Slide(©) ligatures (Leone, Firenze, Italy) coupled with various S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2014