Measurement of magnesium by continuous-flow colorimetry.

نویسندگان

  • R T Fowler
  • M H Abernethy
  • T A Walmsley
  • H W Taylor
چکیده

We describe the application to the Technicon SMAC system of a micellar-improved calmagite method for the measurement of magnesium. In this continuous-flow method a dialyzer is not needed, because protein interference is negligible. Sample interaction was estimated to be 3%. The increased sensitivity of the method allows for a small sample volume (37 microL/min). Results obtained agreed well with those by an atomic absorption procedure (x): SMAC magnesium - 0.971 x + 0.030 mmol/L (n = 58). The estimated total error for the SMAC procedure was less than 50 mumol/L at two analyte concentrations: 0.50 and 1.50 mmol/L. The inclusion of magnesium estimation on SMAC should extend the screening function of this analyzer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid, simplified continuous-flow colorimetry of serum triglycerides.

analysis on the 15-channel instrument. Consequently, erythrocyte indices can be measured, when indicated, afteranalysison the 15-channelinstrument. In summary, we have demonstrated that screening for GPD deficiency and hemoglobin S isfeasibleat a rateof 120/hour when coupled to the 15-channel instrument. The reverse-washout cycle on the sample probe of the bloodtyping instrument obviates sample...

متن کامل

Manual and continuous-flow colorimetry of triacylglycerols by a fully enzymic method.

We describe a fully enzymic method for manual and continuous-flow colorimetric assay of triacylglycerols (triglycerides) in serum. Triglycerides are enzymically hydrolyzed in 10 min by lipase and microbial esterase. The resulting free glycerol is measured enzymically by glycerol kinase and glycerol-3-phosphate dehydrogenase. The NADH so formed is oxidized by coupling with a tetrazolium salt/dia...

متن کامل

Rapid colorimetry of zinc in seminal fluid.

This colorimetric method for determination of zinc in seminal liquid is based on the reaction between zinc and 4-(2-pyridylazo)resorcinol in a buffered solution at pH 9.5. It is very simple, fast (approximately equal to 10 min), and economical. It can be used to determine zinc in "whole" semen, seminal plasma, or isolated spermatozoa. We verified its accuracy for sample concentrations up to 0.4...

متن کامل

Determination of Serum Calcium by Means of Sodium Alizarinsulfonate.

1’T”HEUSE OF alizarin (1,2-dihydroxyanthraquinone) as an analytical reagent for calcium in biological materials was first described by Laidlaw and Payne in 1922 (1). The calcium was first isolated as oxalate. This was converted into insoluble calcium alizarinate which was dissolved and subjected to colorimetry. Although 100 g. of calcium can be determined by tilis method, it requires much manip...

متن کامل

Rapid measurement of arterial input function in mouse tail from projection phases.

PURPOSE To measure the arterial input function (AIF) in a mouse tail at high temporal resolution with signal phase of MR projections. METHODS The technique involves the acquisition of one 2D image before injection, followed by a series of projections before, during, and after contrast injection. Differences in the signal phase, relative to the mean preinjection phase, were calculated and conv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 28 3  شماره 

صفحات  -

تاریخ انتشار 1982