A biomechanical evaluation of all-inside 2-stitch meniscal repair devices with matched inside-out suture repair.
نویسندگان
چکیده
BACKGROUND Many all-inside suture-based devices are currently available, including the Meniscal Cinch, FasT-Fix, Ultra FasT-Fix, RapidLoc, MaxFire, and CrossFix System. These different devices have been compared in various configurations, but to our knowledge, the Sequent meniscal repair device, which applies running sutures, has not been compared with the Ultra FasT-Fix, nor has it been compared with its suture, No. 0 Hi-Fi, using an inside-out repair technique. PURPOSE To assess the quality of the meniscal repair, all new devices should be compared with the gold standard: the inside-out repair. To that end, this study aims to compare the biomechanical characteristics of running sutures delivered by the Sequent meniscal repair device with 2 vertical mattress sutures applied using the Ultra FasT-Fix device and with 2 vertical mattress sutures using an inside-out repair technique with No. 0 Hi-Fi suture. STUDY DESIGN Controlled laboratory study. METHODS Paired (medial and lateral), fresh-frozen porcine menisci were randomly assigned to 1 of 3 groups: Sequent (n = 17), Ultra FasT-Fix (n = 19), and No. 0 Hi-Fi inside-out repair (n = 20). Bucket-handle tears were created in all menisci and were subjected to repair according to their grouping. Once repaired, the specimens were subjected to cyclic loading (100, 300, and 500 cycles), followed by loading to failure. RESULTS The Sequent and Ultra FasT-Fix device repairs and the suture repair exhibited low initial displacements. The Sequent meniscal repair device demonstrated the lowest displacement in response to cyclic loading. No. 0 Hi-Fi suture yielded the highest load to failure. CONCLUSION With the development of the next generation of all-inside meniscal repair devices, surgeons may use these findings to select the method best suited for their patients. CLINICAL RELEVANCE The Sequent meniscal repair device displays the least amount of displacement during cyclic loading but has a similar failure load to other devices.
منابع مشابه
Human Mesenchymal Stem Cell-derived Exosomes Promote Orderly Cartilage Regeneration in an Immunocompetent Rat Osteochondral Defect Model
Background : Although meniscal repair techniques have developed for several decades, meniscal repair of radial tears still remains challenging issue. For successful meniscal healing of radial tears, primary mechanical stability of meniscal repair is one of the essential requirements. All-inside vertical suture and Cross-suture techniques have been reported to provide superior stability compared...
متن کاملArthroscopic Meniscal Repair: “Modified Outside-In Technique”
Background: Despite the introduction of different techniques for meniscal repair, no single procedure is superior in all situations. The new method for meniscal repair named “ modified outside-in technique ” aims to achieve higher primary fixation strength by an alternative suture technique as well as avoid disadvantages of outside-in, inside-out, and all-inside suture procedures. Additionally...
متن کاملBiomechanical testing of transcapsular meniscal repair
BACKGROUND All of previous biomechanical studies on meniscal repair have examined the meniscus itself without synovial membrane and capsule, although in the clinical setting, the meniscal repair is generally performed including capsule. Therefore, biomechanical properties of transcapsular meniscal repair are unclear. Thus, this study aimed to clarify the biomechanical properties of transcapsula...
متن کاملAll-inside Arthroscopic Meniscal Repair Technique Using a Midbody Accessory Portal
Treatment of symptomatic meniscal tears continues to evolve as we improve our understanding of the biomechanical role of the meniscus and its long-term importance to the health of the knee joint. Suture repair of meniscal tears is challenging, yet the incidence of repairs among our colleagues continues to rise as we aim to preserve meniscal tissue. Many elements of performing a repair are tedio...
متن کاملShear force at failure and stiffness of all-inside meniscal repair devices.
The purpose of this study was to determine the failure load and stiffness of various meniscal repair devices. A total of 61 fresh-frozen porcine menisci (medial and lateral) were used for the study. A 30-mm vertical, full-thickness tear was created and repaired using one of three all-inside fixation devices and one inside-out repair in the vertical mattress pattern. We used the MaxBraid (Biomet...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The American journal of sports medicine
دوره 42 1 شماره
صفحات -
تاریخ انتشار 2014