Transesophageal Echocardiography as the Sole Guidance for Occlusion of Patent Ductus Arteriosus using a Canine Ductal Occluder in Dogs
نویسندگان
چکیده
BACKGROUND Transcatheter occlusion of patent ductus arteriosus (PDA) is usually performed by fluoroscopy alone or together with transesophageal echocardiography (TEE). Transthoracic echocardiography (TTE) guidance has been used for deployment of Amplatz Canine Ductal Occluder (ACDO), but sometimes is limited by suboptimal acoustic windows. Transesophageal echocardiography can overcome such issues and provides higher image resolution at the level of the great vessels. OBJECTIVES To determine if TEE without fluoroscopy could be used to successfully perform ductal occlusion for the treatment of PDA in dogs. ANIMALS Twenty client-owned dogs with PDA. METHODS A prospective consecutive case series of PDA occlusion was performed using only TEE guidance. Dogs were positioned in right lateral recumbency and the TEE probe was positioned to visualize the descending aorta, PDA, and pulmonary artery. The guide wire, long introducer sheath, and ACDO were imaged by TEE to direct deployment. RESULTS Ductal occlusion was performed successfully without need for fluoroscopy and without complications in 19 dogs. One dog required a second larger ACDO because of embolization of the first device 18 hours after positioning. CONCLUSIONS AND CLINICAL IMPORTANCE We have demonstrated that TEE monitoring without concurrent fluoroscopy can guide each step of transcatheter ACDO embolization thereby providing an alternate method of visualization for this procedure. Use of TEE alone can reduce radiation exposure or is an option when fluoroscopy is not available, and, therefore, should be evaluated in a larger case series to better assess procedural failure rates.
منابع مشابه
Relationship between Device Size and Body Weight in Dogs with Patent Ductus Arteriosus Undergoing Amplatz Canine Duct Occluder Deployment
BACKGROUND Deployment of the Amplatz Canine Duct Occluder (ACDO) is the preferred method for minimally invasive occlusion of patent ductus arteriosus (PDA) in dogs, with appropriate device sizing crucial to successful closure. Dogs of any body weight can be affected by PDA. OBJECTIVES To describe the range of ACDO sizes deployed in dogs of various body weights for improved procedural planning...
متن کاملSuccessful transcatheter closure of a residual patent ductus arteriosus with complex anatomy after surgical ligation using an amplatzer ductal occluder guided by live three-dimensional transesophageal echocardiography.
Residual patent ductus arteriosus (PDA) after surgical ligation is not common, but the anatomy of the residual duct may be distorted by the surgical ligation resulting in a difficult transcatheter closure. Such distorted anatomy of the duct may not be demonstrated by the two-dimensional transesophageal echocardiography (2D TEE). Fortunately, live 3D TEE provided the precise anatomy of the elong...
متن کاملInterventional Closure of a Patent Ductus Arteriosus Using an Amplatz Canine Duct Occluder in an Alpaca Cria
A 6-month old female alpaca cria presented to The Ohio State University for evaluation of a cardiac murmur. Echocardiography revealed a left-to-right shunting patent ductus arteriosus, a restrictive left-to-right shunting perimembranous ventricular septal defect, and secondary moderate left atrial and ventricular dilation. Aortic root angiography demonstrated a type IIA patent ductus arteriosus...
متن کاملTransesophageal echocardiography guided patent ductus arteriosus occlusion in adults with severe pulmonary hypertension through a parasternal approach.
Between April 2010 and April 2014, 39 consective adult patients (> 18 years) with PDA associated severe pulmonary hypertension underwent transesophageal echocardiography guided patent ductus arteriosus occlusion through a parasternal minimally invasive approach. Among 39 patients, the procedure was successful in 32 cases (82.1%) and failed in 7 cases (17.9%). In the failed cases, 3 cases had a ...
متن کاملTranscatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.
Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 28 شماره
صفحات -