BACKGROUND AND PURPOSE Low-porosity endoluminal devices for the treatment of intracranial aneurysms, also known as flow diverters, have been in experimental and clinical use for close to 10 years. Despite rigorous evidence of their safety and efficacy in well-controlled trials, a number of key factors concerning their use remain poorly defined. Among these, none has received more attention to date than the debate on how many devices are optimally required to achieve a safe, effective, and economical outcome. Additional, related questions concern device sizing relative to the parent artery and optimal method of deployment of the devices. While some or all of these issues may be ultimately answered on an empiric basis via subgroup analysis of growing treatment cohorts, we believe that careful in vitro examination of relevant device properties can also help guide its in vivo use. MATERIALS AND METHODS We conducted a number of benchtop experiments to investigate the varied porosity of Pipeline Embolization Devices deployed in a simulated range of parent vessel diameters and applied these results toward conceptualizing optimal treatment strategies of fusiform and wide-neck aneurysms. RESULTS The results of our studies confirm a predictable parabolic variability in device porosity based on the respective comparative sizes of the device and recipient artery, as well as device curvature. Even modest oversizing leads to a significant increase in porosity. CONCLUSIONS The experiments demonstrate various deleterious effects of device oversizing relative to the parent artery and provide strategies for addressing size mismatches when they are unavoidable.
منابع مشابه
Semi-active Control of Building Structures using Variable Stiffness Device and Fuzzy Logic
Semi-active control devices, also called “Intelligent” control devices, constitute the positive aspects of both the passive and active control devices. A semi-active control strategy is similar to the active control strategy, but this control device has been shown to be more energy-efficient than active devices. A particular type of semi-active control device, the Variable Stiffness Device (VSD...
متن کاملDelayed retraction of the pipeline embolization device and corking failure: pitfalls of pipeline embolization device placement in the setting of a ruptured aneurysm.
BACKGROUND AND IMPORTANCE The safety of flow-diverting stents for the treatment of ruptured intracranial aneurysms is unknown. CLINICAL PRESENTATION A 35-year-old woman with a ruptured dissecting aneurysm of the intradural right vertebral artery and incorporating the right posterior inferior cerebellar artery was treated with a Pipeline Embolization Device (PED). Five days after reconstructio...
متن کاملBuckling Analysis of Variable Stiffness Composite Laminates by Semi-Analytical Finite Strip Method
Plates made of laminated composite materials with variable stiffness can have wide applications in various branches of engineering due to such advantages as high strength /stiffness to weight ratio. In these composites, curved fibers are used to reinforce each lamina instead of the straight fibers. In this paper, the application of finite strip method for the buckling analysis of moderately thi...
متن کاملOptimal Strategies of Increasing Business Alignment, in Social Security Organization, with Quality Function Deployment (QFD) Approach
Considering the importance of the concept of strategic alignment of information technology (IT) in today economic organizations, this study attempted to extract the organization's IT strategies in order to increase the degree of strategic alignment and consequently the optimal strategies in the field of marketing and service delivery for social security organization. Using QFD technique and hie...
متن کاملBeam & Shell Models for Composite Straight or Curved Bridge Decks with Intermediate Diaphragms & Assessment of Design Specifications
In this research effort, the generalized warping and distortional problem of straight or horizontally curved composite beams of arbitrary cross section, loading and boundary conditions is presented. An inclined plane of curvature is considered. Additionally, the stiffness of diaphragmatic plates has been introduced in the formulation in order to compare with the case where rigid diaphragms are ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2014