On the Connection Between the Correction and Weighting Functions in the Correction Procedure via Reconstruction Method

نویسندگان

  • Meilin Yu
  • Zhi Jian Wang
چکیده

In this note, the connection between the correction and weighting functions for the correction procedure via reconstruction (CPR) method in 1D is addressed. A one-parameter family of weighting functions is constructed from the discontinuous test space. It is found that if the solution polynomials lie in the space P k , then the first k weighting functions can always be chosen as the basis of the polynomial space P k−1 and the last weighting function can be selected as a piece-wise continuous polynomial. There exists at least one set of weighting functions which can recover the energy stable flux reconstruction (ESFR) schemes. This strategy has been successfully applied to recover several known high-order discontinuous schemes, including DG, SD, SV, and Huynh’s g2 scheme.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Attenuation Correction in SPECT during Image Reconstruction using an Inverse Monte Carlo Method: A Simulation Study

Introduction: The main goal of SPECT imaging is to determine activity distribution inside the organs of the body. However, due to photon attenuation, it is almost impossible to do a quantitative study. In this paper, we suggest a mathematical relationship between activity distribution and its corresponding projections using a transfer matrix. Monte Carlo simulation was used to find a precise tr...

متن کامل

The Impact of Correction for Guessing Formula on MC and Yes/No Vocabulary Tests' Scores

A standard correction for random guessing (cfg) formula on multiple-choice and Yes/Noexaminations was examined retrospectively in the scores of the intermediate female EFL learners in an English language school. The correctionwas a weighting formula for points awarded for correct answers,incorrect answers, and unanswered questions so that the expectedvalue of the increase in test score due to g...

متن کامل

A model based, anatomy dependent method for ultra-fast creation of primary SPECT projections

  Introduction: Monte Carlo (MC) is the most common method for simulating virtual SPECT projections. It is useful for optimizing procedures, evaluating correction algorithms and more recently image reconstruction as a forward projector in iterative algorithms; however, the main drawback of MC is its long run time. We introduced a model based method considering the eff...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • J. Sci. Comput.

دوره 54  شماره 

صفحات  -

تاریخ انتشار 2013