Ac 2007-2420: a Small, High-fidelity Reflectance Pulse Oximeter

نویسندگان

  • David Thompson
  • Steve Warren
چکیده

Pulse oximeters have become standard equipment in both biomedical education and clinical settings. Since the operational principles of a pulse oximeter are straightforward, and since the analysis of these sensor data require basic computational and mathematical toolsets, this type of device is well suited to hands-on experiences geared toward both undergraduate and graduate students. However, this seemingly simple type of biomedical device offers challenges in the areas of motion artifact reduction, light excitation/collection, signal fidelity, and parameter extraction that provide rich material for undergraduate and graduate education and research. This paper addresses a new design for a silver-dollar-sized reflectance pulse oximeter that is easy for students to use and incorporates multiple design enhancements that result in high-quality photo-plethysmograms. The pulse oximeter communicates with a LabVIEW virtual instrument via a serial USB interface. The double sided pulse oximeter board contains surface mount circuitry on one side and a reflectance sensor on the other side, where large area photodiodes are arranged radially around a central, dual red & near-infrared LED excitation source. The pulse oximeter is unique in that it is entirely digitally controlled and adjusts signal baselines depending on existing light levels. Additionally, it provides high fidelity red and near-infrared plethysmograms that demonstrate hundreds of analog-to-digital converter levels from peak to valley. Because the plethysmograms are unfiltered, they are good candidates for education and research projects that address signal filtering, blood oxygen saturation calculation algorithms, physiological parameter extraction from photo-plethysmographic signals, light/tissue interaction modeling, and the use of photo-plethysmograms in applications such as biometric authentication. These new devices have been employed in (a) a Fall 2006 lecture/laboratory pair within a biomedical instrumentation course sequence taken by undergraduate and graduate students, (b) undergraduate honors research experiences, and (c) graduate signal processing research.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

INVESTIGATION OF PHOTOPLETHYSMMOGRAPHIC SIGNALS AND ARTERIAL BLOOD OXYGEN SATURATION VALUES (SpO2) DURING BLOOD PRESSURE CUFF-INDUCED HYPOPERFUSION

Photoplethysmography is a non-invasive electro-optical technique widely used in the study and monitoring of the pulsations associated with changes in blood volume in a peripheral vascular bed. Photoplethysmography is used in the estimation of arterial oxygen saturation (SpO2) by pulse oximetry. A reflectance finger photoplethysmographic (PPG) probe and a multiplexed data acquisition system oper...

متن کامل

Arterial Blood Oxygen Saturation during Blood Pressure Cuff-induced Hypoperfusion

Pulse oximetry has been one of the most significant technological advances in clinical monitoring in the last two decades. Pulse oximetry is a non-invasive photometric technique that provides information about the arterial blood oxygen saturation (SpO2) and heart rate, and has widespread clinical applications. When peripheral perfusion is poor, as in states of hypovolaemia, hypothermia and vaso...

متن کامل

Monitoring respiration rate in PACU patients using the plethysmogram from a pulse oximeter

Introduction Post-operative patients with undiagnosed obstructive sleep apnea are at risk of sudden respiratory failure after receiving anesthesia because of repressed respiratory and hemodynamic responses [1] . While all patients have their oxygen saturation automatically monitor in the Post Anesthesia Care Unit (PACU), few have their respiration rate monitored. The goal of our study is to dev...

متن کامل

The Effect of Tracheal Intubation-Induced Autonomic Response on Photoplethysmography

Introduction. Intraoperative stress responses and postoperative pain can be monitored using photoplethysmography (PPG). PPG signal has two components, AC and DC. Effects of noxious stimuli-induced stress responses have not been studied on the DC component of PPG. The aim of this study was to investigate the effect of a known noxious stimulus (endotracheal intubation) on both the AC and DC compo...

متن کامل

Monitoring respiration rate in PACU patients using the plethysmogram from a commercial pulse oximeter

Introduction Post-operative patients with undiagnosed obstructive sleep apnea are at risk of sudden respiratory failure after receiving anesthesia because of repressed respiratory and hemodynamic responses [1]. While all patients have their oxygen saturation monitored in the Post Anesthesia Care Unit (PACU), few have their respiration rate monitored. The respiratory rate could be used to detect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007