Real-Time Quality Control of Tracked Ultrasound
نویسندگان
چکیده
The overwhelming majority of intra-operative hazard situations in tracked ultrasound (US) systems are attributed to failure of registration between tracking and imaging coordinate frames. We introduce a novel methodology for eal-time in-vivo quality control of tracked US systems, in order to capture registration failures during the clinical procedure. In effect, we dynamically recalibrate the tracked US system for rotation, scale factor, and in-plane position offset up to a scale factor. We detect any unexpected change in these parameters through capturing discrepancies in the resulting calibration matrix, thereby assuring quality (accuracy and consistency) of the tracked system. No phantom is used for the recalibration. We perform the task of quality control in the background, transparently to the clinical user while the subject is being scanned. We present the concept, mathematical formulation, and experimental evaluation in-vitro. This new method can play an important role in guaranteeing accurate, consistent, and reliable performance of tracked ultrasound.
منابع مشابه
Real-Time Processing of Three Dimensional Ultrasound for Intracardiac Surgery
Real-time three-dimensional ultrasound has been demonstrated as a viable tool for guiding surgical procedures. This visualization technique enables a range of new minimally invasive techniques in cardiac surgery. Ultrasound permits visualization through the opaque blood pool in the heart, and the advent of real-time 3DUS overcomes difficulties with 3D spatial perception in conventional 2D ultra...
متن کاملDetection of HSV Infection in Patients with Sudden Sensory-Neural Hearing Loss (SSNHL) by Real-time PCR
Background and Aims: Sudden sensorineural hearing loss (SSNHL) is a common disorder diagnosed in otologic and audiologic practices. Its accompanying symptoms include tinnitus, dizziness, and permanent hearing loss affecting negatively the life quality of affected patients. Many viruses have been involved in the occurrence of SSNHL especially Herpes simplex virus (HSV) type I and II. This study ...
متن کاملA Reliable Real Time Liver Motion Tracking for Application in Magnetic Resonance guided High Intensity Focused Ultrasound Therapy
Introduction High-intensity focused ultrasound has shown potential for ablating liver tumors without the need for surgical procedures [1]. However, the long duration of HIFU scans (~2hrs) and the varying respiratory motion requires that features identified for sonication be tracked in real time during the procedure [2]. The real time tracking would enable a free-breathing MRgFUS treatment and t...
متن کاملInvestigation on Escherichia Coli Inactivation and Some Quality Changes in Carrot Juice by Ultrasound Technique
In this study Response Surface Methodology was used to optimize process conditions and to evaluate the effect of ultrasound on quality attributes (antioxidant activity, pH, total soluble solid, turbidity) and the inactivation of Escherichia coli bacteria in carrot juice. Independent variables in this study were temperature (25-50°C), time (20-40 min) and frequency (0-130 kHz). In this study the...
متن کاملInvestigation on Escherichia Coli Inactivation and Some Quality Changes in Carrot Juice by Ultrasound Technique
In this study Response Surface Methodology was used to optimize process conditions and to evaluate the effect of ultrasound on quality attributes (antioxidant activity, pH, total soluble solid, turbidity) and the inactivation of Escherichia coli bacteria in carrot juice. Independent variables in this study were temperature (25-50°C), time (20-40 min) and frequency (0-130 kHz). In this study the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 8 Pt 1 شماره
صفحات -
تاریخ انتشار 2005