Calibration of an in situ membrane inlet mass spectrometer for measurements of dissolved gases and volatile organics in seawater.

نویسندگان

  • Ryan J Bell
  • R Timothy Short
  • Friso H W van Amerom
  • Robert H Byrne
چکیده

Use of membrane inlet mass spectrometers (MIMS) for quantitative measurements of dissolved gases and volatile organics over a wide range of ocean depths requires characterization of the influence of hydrostatic pressure on the permeability of MIMS inlet systems. To simulate measurement conditions in the field, a laboratory apparatus was constructed for control of sample flow rate, temperature, pressure, and the concentrations of a variety of dissolved gases and volatile organic compounds. MIMS data generated with this apparatus demonstrated thatthe permeability of polydimethylsiloxane (PDMS) membranes is strongly dependent on hydrostatic pressure. For the range of pressures encountered between the surface and 2000 m ocean depths, the pressure dependent behavior of PDMS membranes could not be satisfactorily described using previously published theoretical models of membrane behavior. The observed influence of hydrostatic pressure on signal intensity could, nonetheless, be quantitatively modeled using a relatively simple semiempirical relationship between permeability and hydrostatic pressure. The semiempirical MIMS calibration developed in this study was applied to in situ underwater mass spectrometer (UMS) data to generate high-resolution, vertical profiles of dissolved gases in the Gulf of Mexico. These measurements constitute the first quantitative observations of dissolved gas profiles in the oceans obtained by in situ membrane inlet mass spectrometry. Alternative techniques used to produce dissolved gas profiles were in good accord with UMS measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Resolution Measurement of Volatile Organic Compounds Dissolved in Seawater Using Equilibrator Inlet-Proton Transfer Reaction-Mass Spectrometry (EI-PTR-MS)

We have developed an equilibrator inlet-proton transfer reaction-mass spectrometry (EI-PTRMS) system for the high-resolution measurement of the concentrations of multiple volatile organic compounds (VOCs) dissolved in seawater. The equilibration of six VOCs (dimethyl sulfide (DMS), isoprene, propene, acetone, acetaldehyde, and methanol) between seawater samples and the carrier gas, and the resp...

متن کامل

Continuous Measurements of Dissolved Ne, Ar, Kr, and Xe Ratios with a Field-Deployable Gas Equilibration Mass Spectrometer.

Noble gases dissolved in natural waters are useful tracers for quantifying physical processes. Here, we describe a field-deployable gas equilibration mass spectrometer (GEMS) that provides continuous, real-time measurements of Ne, Ar, Kr, and Xe mole ratios in natural waters. Gas is equilibrated with a membrane contactor cartridge and measured with a quadrupole mass spectrometer, after in-line ...

متن کامل

Membrane inlet mass spectrometry for homeland security and forensic applications.

A man-portable membrane inlet mass spectrometer has been built and tested to detect and monitor characteristic odors emitted from the human body and also from threat substances. In each case, a heated membrane sampling probe was used. During human scent monitoring experiments, data were obtained for inorganic gases and volatile organic compounds emitted from human breath and sweat in a confined...

متن کامل

A Review of the Emerging Field of Underwater Mass Spectrometry

Mass spectrometers are versatile sensor systems, owing to their high sensitivity and ability to simultaneously measure multiple chemical species. Over the last two decades, traditional laboratory-based membrane inlet mass spectrometers have been adapted for underwater use. Underwater mass spectrometry (UMS) has drastically improved our capability to monitor a broad suite of gaseous compounds (e...

متن کامل

FOCUS: HARSH ENVIRONMENT MASS SPECTROMETRY Application of Membrane Inlet Mass Spectrometry for Online and In Situ Analysis of Methane in Aquatic Environments

A method is presented for the online measurement of methane in aquatic environments by application of membrane inlet mass spectrometry (MIMS). For this purpose, the underwater mass spectrometer Inspectr200-200 was applied. A simple and reliable volumetric calibration technique, based on the mixing of two end member concentrations, was used for the analysis of CH4 by MIMS. To minimize interferen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 41 23  شماره 

صفحات  -

تاریخ انتشار 2007