A fast and efficient microfluidic system for highly selective one-to-one droplet fusion.

نویسندگان

  • Linas Mazutis
  • Jean-Christophe Baret
  • Andrew D Griffiths
چکیده

Microdroplets in microfluidic systems can be used as independent microreactors to perform a range of chemical and biological reactions. However, in order to add new reagents to pre-formed droplets at defined times, to start, modify, or terminate a reaction, it is necessary to perform a controlled fusion with a second droplet. We describe and characterize a simple and extremely reliable technique for the one-to-one fusion of droplet pairs in a microfluidic system at kHz frequencies. The technique does not require special channel treatment, electrical fields or lasers to induce droplet fusion. Instead, we make use of transient states in the stabilization of the droplet interface by surfactant, coupled to a proper geometrical design of a coalescence module, to induce the selective fusion of a droplet stabilized by surfactant (re-injected) with a droplet which is not fully stabilized (generated on-chip). Using a 1.2-fold excess of the surfactant-stabilized droplets approximately 99% of the partially stabilized droplets were fused one-to-one with surfactant-stabilized droplets. Even when the surfactant-stablized droplets were in 5-fold excess, over 96% of the partially stabilized droplets were fused one-to-one. The fused droplet contains enough surfactant to inhibit further fusion events. After fusion, the droplets were fully stabilized by additional surfactant provided in the carrier oil, which allowed the fused droplets to be collected, incubated off-chip and re-injected onto a microfluidic device without any undesired coalescence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selective droplet coalescence using microfluidic systems.

We report a microfluidic approach, which allows selective and controlled 1 : 1, 2 : 1 or 3 : 1 droplet fusion. A surfactant-stabilized droplet with an interfacial surfactant coverage, Γ, of >98% will fuse spontaneously with a second droplet when Γ of the latter droplet is <16%. However, when Γ of the second droplet is ~66%, the two droplets will not fuse, unless they have previously been brough...

متن کامل

Numerical Study of Droplet Generation Process in a Microfluidic Flow Focusing

Microfluidic flow focusing devices have been utilized for droplet generation on account of its superior control over droplet size. Droplet based microfluidics addressed many scientific issues by providing a novel technological platform for applications such as biology, pharmaceutical industry, biomedical studies and drug delivery. This study numerically investigated the droplet generation proce...

متن کامل

Multi-step microfluidic droplet processing: kinetic analysis of an in vitro translated enzyme.

Microdroplets in water-in-oil emulsions can be used as microreactors with volumes 10(3) to 10(9) times smaller than the smallest working volumes in a microtitre plate well (1-2 microL). However, many reactions and assays require multiple steps where new reagents are added at defined times, to start, modify or terminate a reaction. The most flexible way to add new reagents to pre-formed droplets...

متن کامل

Calculation of One-dimensional Forward Modelling of Helicopter-borne Electromagnetic Data and a Sensitivity Matrix Using Fast Hankel Transforms

The helicopter-borne electromagnetic (HEM) frequency-domain exploration method is an airborne electromagnetic (AEM) technique that is widely used for vast and rough areas for resistivity imaging. The vast amount of digitized data flowing from the HEM method requires an efficient and accurate inversion algorithm. Generally, the inverse modelling of HEM data in the first step requires a precise a...

متن کامل

Fluorescent Contrast agent Based on Graphene Quantum Dots Decorated Mesoporous Silica Nanoparticles for Detecting and Sorting Cancer Cells

Background and Objectives: The inability of classic fluorescence-activated cell sorting to single cancer cell sorting is one of the most significant drawbacks of this method. The sorting of cancer cells in microdroplets significantly influences our ability to analyze cancer cell proteins. Material and Methods: We adapted a developed microfluidic device as a 3D in vitro model to sorted MCF-7 c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 9 18  شماره 

صفحات  -

تاریخ انتشار 2009