Maximal Oxygen Consumption, Respiratory Volume and Some Related Factors in Fire-fighting Personnel

نویسندگان

  • Touraj Khazraee
  • Mohammad Fararouei
  • Hadi Daneshmandi
  • Farzane Mobasheri
  • Zahra Zamanian
چکیده

BACKGROUND Firefighters for difficult activities and rescue of damaged people must be in appropriate physical ability. Maximal oxygen capacity is an indicator for diagnosis of physical ability of workers. This study aimed to assess the cardiorespiratory system and its related factors in firefighters. METHODS This study was conducted on 110 firefighters from various stations. An self-administered questionnaire (respiratory disorders questionnaire, Tuxworth-Shahnavaz step test, and pulmonary function test) was used to collection of required data. Average of humidity and temperature was 52% and 17°C, respectively. Background average noise levels were between 55 and 65 dB. Data were analyzed using SPSS software (version 19). RESULTS The mean age of the study participants was 32 ± 6.2 years. The means of forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and FEV1/FVC were 92% ±9.4%, 87% ±9.2%, and 80% ±6.1%, respectively. The participants' mean VO2-max was 2.79 ± 0.29 L/min or 37.34 ± 4.27 ml/kg body weight per minute. The results revealed that weight has a direct association with vital capacity (VC), FVC, and peak expiratory flow. In addition, height was directly associated with VC, FVC, and VO2-max (P < 0.05). However, there was an inverse and significant association between height and FEV1/FVC (r = -0.23, P < 0.05). Height, weight, body mass index, and waist circumference were directly associated with VO2-max. CONCLUSIONS The findings of this study showed that the amount of maximum oxygen consumption is close with the proposed range of this parameter among firefighters in other studies. Furthermore, the results of the study revealed that individuals had normal amounts of lung volume index. This issue can be attributed to the appropriate usage of respiratory masks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Relationships among Occupational Stress, Alcohol Dependence and Other Factors in Male Personnel in a Japanese Local Fire Fighting Organization

Recent large-scale disasters have made middle-ranked fire defense officers responsible for routine fire fighting activities, and a tendency of alcohol dependence associated with other stressful problems is noted in Japan. We assessed the alcohol dependence tendency with the alcohol use disorders identification test (AUDIT) in firefighters. Occupational stress, depression and other factors were ...

متن کامل

Acute and chronic effects of fire fighting on pulmonary function.

The acute and chronic effects of fire fighting on pulmonary function were studied in 54 fire fighters from Connecticut, 32 smokers and 22 nonsmokers. Baseline studies of maximum expiratory flow-volume curves while breathing air and a mixture of 80 percent helium and 20 percent oxygen revealed obstruction of the small airways in 35 percent (nine) of 26 smokers and 13 percent (two) of 15 nonsmoke...

متن کامل

Energy cost of the Trondheim firefighter test for experienced firefighters.

AIM The aim of this study was to measure aerobic demands of fire fighting activities including exercise in the heat. METHODS Twenty-two experienced firefighters performed the Trondheim test simulating fire fighting tasks including work in the heat. Maximal oxygen uptake (VO2 max), heart rate (HR) and ventilation were recorded continuously. Data were compared with results obtained during a tre...

متن کامل

Comparative study of some blood respiratory factors between mudskipper, Scartelaos tenuis and mullet, Liza klunzingeri in the Persian Gulf, Hormozgan province

Fish depend on water to supply oxygen demand. Blood plays an important role in oxygen transport. Differences in oxygen uptake, resulting in special blood respiratory factors are arisen from diverse living styles. In this study, blood respiratory factors compared between mudskipper, Scartelaos tenuis, and Liza klunzingeri. Samples were taken from Bandar abbas shore line. Blood sampling was perfo...

متن کامل

The Relationship Between Peak Oxygen Consumption and Pulmonary Function Indices: Measured by Spirometry and Allometry Equation in Male Students

Purpose: Allometry is a method to express the relationship between physiological and anatomical variables. It can be used to measure the vital capacity through mathematical equations. This study aimed at evaluating lung function indices to estimate the maximal aerobic power by respiratory gas analysis device and the allometric equation. Methods: This study was a descriptive and correlational r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2017