Wideband acoustic immittance for assessing middle ear functioning for preterm neonates in the neonatal intensive care unit
نویسندگان
چکیده
BACKGROUND The primary aim of newborn hearing screening is to detect permanent hearing loss. Because otoacoustic emissions (OAEs) and automated auditory brainstem response (AABR) are sensitive to hearing loss, they are often used as screening tools. On the other hand, false-positive results are most often because of transient outer- and middle ear conditions. Wideband acoustic immittance (WAI), which includes physical measures known as reflectance and absorbance, has shown potential for accurate assessment of middle ear function in young infants. OBJECTIVE The main objective of this study was to determine the feasibility of WAI as a diagnostic tool for assessing middle ear functioning in preterm neonates in the neonatal intensive care unit (NICU) designed for premature and ill neonates. A further objective was to indicate the difference between the reflectance values of tones and click stimuli. METHOD Fifty-six at-risk neonates (30 male and 26 female), with a mean age at testing of 35.6 weeks (range: 32-37 weeks) and a standard deviation of 1.6 from three private hospitals, who passed both the distortion product otoacoustic emission (DPOAE) and AABR tests, were evaluated prior to discharge from the NICU. Neonates who presented with abnormal DPOAE and AABR results were excluded from the study. WAI was measured by using chirp and tone stimuli. In addition to reflectance, the reflectance area index (RAI) values were calculated. RESULTS Both tone and chirp stimuli indicated high-power reflectance values below a frequency of 1.5 kHz. Median reflectance reached a minimum of 0.67 at 1 kHz - 2 kHz but increased to 0.7 below 1 kHz and 0.72 above 2 kHz for the tone stimuli. For chirp stimuli, the median reflectance reached a minimum of 0.51 at 1 kHz - 2 kHz but increased to 0.68 below 1 kHz and decreased to 0.5 above 2 kHz. A comparison between the present study and previous studies on WAI indicated a substantial variability across all frequency ranges. CONCLUSION These WAI measurements conducted on at-risk preterm NICU neonates (mean age at testing: 35.6 weeks, range: 32-37 weeks) identified WAI patterns not previously reported in the literature. High reflective values were obtained across all frequency ranges. The age of the neonates when tested might have influenced the results. The neonates included in the present study were very young preterm neonates compared to the ages of neonates in previous studies. WAI measured in at-risk preterm neonates in the NICU was variable with environmental and internal noise influences. Transient conditions affecting the sound-conduction pathway might have influenced the results. Additional research is required to investigate WAI testing in ears with and without middle ear dysfunction. The findings of the current study imply that in preterm neonates it was not possible to determine the feasibility of WAI as a diagnostic tool to differentiate between ears with and without middle ear pathology.
منابع مشابه
High frequency immittance for neonates: a normative study.
CONCLUSION High frequency immittance measurements demonstrate promise in clarifying middle ear status for neonates but age- and gender-specific norms should be consulted. OBJECTIVE To describe high frequency immittance measurements using a 1000 Hz probe tone for a sample of 278 neonatal ears (0-4 weeks of age) in order to compile normative tympanometric and acoustic reflex criteria. SUBJECT...
متن کاملAssessing the Performance of Nurses in the Proper Adjustment of Monitoring Instruments in the Neonatal Intensive Care Unit
Background: Monitoring serves to maintain physiologic variables within normal limits and when a parameter crosses a set threshold, an alarm is triggered. Therefore, this study aimed to determine whether alarm limits are properly adjusted in the neonatal intensive care unit (NICU) by nursing staff or not.Methods: The data concerning alarm limits corresponding to the three shifts of nursing...
متن کاملHome-based Care Needs of Preterm Infants Discharged Early from the Neonatal Intensive Care Unit: A Descriptive Qualitative Study
Background: Prematurity could result in the long admission of the neonate to the Neonatal Intensive Care Unit (NICU) and development of some complications for both mother and newborn. The early discharge programs make the neonatal transference to home much easier and are beneficial to both parents and newborns. However,there are limited studies investigating the real needs of the preterm neonat...
متن کاملEffect of Clustered Nursing Care on Sleep Behaviors of the Preterm Neonates Admitted to the Neonatal Intensive Care Unit
Background: Premature neonates admitted to the neonatal intensive care unit (NICU) undergo sleep disorder due to various manipulations. The present study aimed to investigate the effect of clustered nursing care on sleep behaviors in premature neonates admitted to NICUs. Methods: This clinical trial study was conducted on 60 neonates sel...
متن کاملComparative Study of Hearing Impairment among Healthy and Intensive Care unit Neonates in Mashhad, North East Iran
Introduction: According to World Health Organization (WHO) 2001 statistics, hearing disorders are the most common congenital disease, and the incidence rate among high-risk newborns is as much as ten times as high as that in healthy neonates. However, 78% of screening test failures are well-baby nursery babies. The Joint Committee on Infants’ Hearing (JCIH) has emphasized the importance of earl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 64 شماره
صفحات -
تاریخ انتشار 2017