A prospective randomised double-blind study of functional outcome and range of flexion following total knee replacement with the NexGen standard and high flexion components.
نویسندگان
چکیده
Modifications in the design of knee replacements have been proposed in order to maximise flexion. We performed a prospective double-blind randomised controlled trial to compare the functional outcome, including maximum knee flexion, in patients receiving either a standard or a high flexion version of the NexGen legacy posterior stabilised total knee replacement. A total of 56 patients, half of whom received each design, were assessed pre-operatively and at one year after operation using knee scores and analysis of range of movement using electrogoniometry. For both implant designs there was a significant improvement in the function component of the knee scores (p < 0.001) and the maximum range of flexion when walking on the level, ascending and descending a slope or stairs (all p < 0.001), squatting (p = 0.020) and stepping into a bath (p = 0.024). There was no significant difference in outcome, including the maximum knee flexion, between patients receiving the standard and high flexion designs of this implant.
منابع مشابه
Gender-specific high-flexion knee prosthesis in Indian women: a prospective randomised study.
PURPOSE To compare outcomes in Indian women who underwent total knee arthroplasty (TKA) using the standard Legacy Posterior Stabilised (LPS) versus the gender-specific LPS high-flexion knee prosthesis. METHODS 100 women (200 knees) aged 60 to 80 years with an arc of flexion of ≥90º underwent simultaneous sequential TKA for primary osteoarthritis of both knees. They were randomised to receive ...
متن کاملHigh Flexion Total Knee Arthroplasty – Mid-Term Follow Up of 5 Years
Because of demographic changes, ever greater demands are made of knee replacement systems by patients and surgeons. To meet these demands, knee joint systems with increased flexion are currently being marketed. The main hypothesis of the present study was to evaluate the functional outcome of a high flexion TKA in amid-term follow up. 75 consecutive patients (29 men and 46 women) who had primar...
متن کاملStudy of knee range of motion after soft tissue repair in both flexion and extension during total knee arthroplasty: a randomized clinical trial
Background: The patient's position during the recovery time after arthroplasty surgery can be a factor in reducing complications and improving patients’ condition. Therefore, this study was performed to compare the knee range of motion after soft tissue repair in both flexion and extension positions of total knee arthroplasty. Methods: This study is a double-blind clinical trial. The study pop...
متن کاملRetrospective comparison of functional and radiological outcome, between two contemporary high flexion knee designs
INTRODUCTION Patient satisfaction after total knee replacement (TKR) depends on the amount of pain relief and the functional activities achieved. An important criterion of good functional outcome is the amount of flexion achieved and whether the patient can manage high flexion activities. In order to increase the amount of safe flexion, various implant designs have been developed. This study ai...
متن کاملRange of Motion In High Flexion Total Knee Arthroplasty vs. Standard Posterior Stabilized Total Knee Arthroplasty A Prospective, Randomized Study
Range of motion after knee replacement is an important factor in overall outcome. The purpose was to compare motion in patients receiving high flexion prosthesis vs. standard prosthesis. 24 high flexion and standard knee prostheses were used. Patients were followed for two years and evaluated prospectively. The mean HSS was 80.4 for the standard group and 80.7 for the flexion group. At two year...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 90 1 شماره
صفحات -
تاریخ انتشار 2008