Determination of time-resolved fluorescence emission spectra and anisotropies of a fluorophore-protein complex using frequency-domain phase-modulation fluorometry.

نویسندگان

  • J R Lakowicz
  • E Gratton
  • H Cherek
  • B P Maliwal
  • G Laczko
چکیده

We report the first time-resolved fluorescence emission spectra and time-resolved fluorescence anisotropies obtained using frequency-domain fluorescence spectroscopy. We examined the fluorophore p-2-toluidinyl-6-naphthalenesulfonic acid (TNS) in viscous solvents and bound to the heme site of apomyoglobin using multifrequency phase fluorometers. Fluorescence phase shift and modulation data were obtained at modulation frequencies ranging from 1 to 200 MHz. For time-resolved emission spectra, the impulse response for the decay of intensity at each emission wavelength was obtained from the frequency response of the sample at the same emission wavelength. The decays have negative pre-exponential factors, consistent with a time-dependent spectral shift to longer wavelengths. These multiexponential decays were used to construct the time-resolved emission spectra, which were found to be in good agreement with earlier spectra obtained from time-domain measurements. Additionally, time-resolved anisotropies were obtained from the frequency-dependent phase angle differences between the parallel and perpendicularly polarized components of the emission. The rotational correlation times of TNS bound to apomyoglobin are consistent with those expected for this probe rigidly bound to the protein. TNS in propylene glycol also displayed a single exponential decay of anisotropy. These results, in conjunction with the previous successful resolution of multiexponential decays of fluorescence intensity (Lakowicz, J. R., Gratton, E., Laczko, G., Cherek, H., and Limkeman, M. (1984) Biophys. J., in press; Gratton, E., Lakowicz, J. R., Maliwal, B. P., Cherek, H., Laczko, G., and Limkeman, M. (1984) Biophys. J., in press) demonstrate that frequency-domain measurements provide information which is, at a minimum, equivalent to that obtainable from time-domain measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time-Resolved Fluorescence Anisotropics of Diphenylhexatriene and Perylene in Solvents and Lipid Bilayers Obtained from Multifrequency Phase-Modulation Fluorometry

Time-resolved decays of fluorescence anisotropy were obtained from frequency-domain measurements of the phase angle difference between the parallel and perpendicular components of the polarized emission and the ratio of the modulated amplitudes. These data were measured at modulation frequencies ranging from 1 to 200 MHz. To demonstrate the general applicability of this method, we describe the ...

متن کامل

Time-resolved fluorescence anisotropies of diphenylhexatriene and perylene in solvents and lipid bilayers obtained from multifrequency phase-modulation fluorometry.

Time-resolved decays of fluorescence anisotropy were obtained from frequency-domain measurements of the phase angle difference between the parallel and perpendicular components of the polarized emission and the ratio of the modulated amplitudes. These data were measured at modulation frequencies ranging from 1 to 200 MHz. To demonstrate the general applicability of this method, we describe the ...

متن کامل

Phase-fluorimetry study on dielectric relaxation of human serum albumin.

The dielectric relaxation (DR) of human serum albumin (HSA) was studied by the method of phase-fluorometry. The protein environment of the single tryptophan in HSA shows a relatively low-speed DR of sub-ns characteristic time. This relaxation can be measured as a decaying red-shift of the time-resolved fluorescence emission spectra. The details of calculations of time-emission matrices (TEM) an...

متن کامل

Simultaneous Determination of Ibuprofen and Caffeine in Urine Samples by Combining MCR-ALS and Excitation-emission Data

Second order advantage of excitation-emission fluorescence matrix was applied for the simultaneous determination of ibuprofen and caffeine. The proposed method is based on the measurement of the native fluorescence and recording emission spectra of ibuprofen and caffeine in different excitation wavelengths. The mixture of these compounds was resolved by multivariate curve resolution coupled wit...

متن کامل

Interaction of a fluorescent analogue of GDP with elongation factor Tu: steady-state and time-resolved fluorescence studies.

A fluorescent derivative of GDP was prepared by the reaction of 2'-amino-2'-deoxy-GDP with fluorescamine. This derivative binds tightly (KD approximately 4.5 X 10(-8) M) to elongation factor Tu (EF-Tu) from Escherichia coli. The emission properties, including spectra, polarizations, and lifetimes, for fluorescamine-GDP free in solution and bound to EF-Tu are presented. Emission data on the fluo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of biological chemistry

دوره 259 17  شماره 

صفحات  -

تاریخ انتشار 1984