Effect of length and diameter of drug-eluting stents versus bare-metal stents on late outcomes.
نویسندگان
چکیده
BACKGROUND The risk of restenosis and other adverse cardiac events with bare-metal stents (BMS) is increased with smaller stent diameters and longer stent lengths. Drug-eluting stents (DES) may reduce this effect in select patients; however, whether this benefit occurs in high-risk lesions and patients in routine practice is not clear. METHODS AND RESULTS Clinical outcomes (target-vessel revascularization [TVR], stent thrombosis, nonfatal myocardial infarction [MI], and cardiac death) at 2 years stratified by stented length and diameter were compared in 949 consecutive patients who received BMS and 1236 consecutive and comparable patients who received DES for single lesions. The longest tertile of BMS (>23 mm) was associated with increased hazard of TVR, ST, and nonfatal MI or death compared with shorter tertiles of BMS, which was abolished by DES. DES compared with BMS was independently associated with a lower hazard of TVR (HR, 0.34 [0.20 to 0.58]) and nonfatal MI or death (HR, 0.60 [0.39 to 0.92]) in the longest length tertile (>23 mm). No clear association of stented tertile diameter and clinical outcomes for either stent type was observed. However, DES compared with BMS was independently associated with a lower hazard of TVR for all diameter tertiles, and a lower hazard of nonfatal MI or death (0.66 [0.44 to 0.99]) in the largest diameter tertile (>3.4 mm). CONCLUSIONS Independent of adverse patient and lesion characteristics, DES demonstrated significantly lower hazard of TVR and nonfatal MI or death at 2 years compared with BMS within the longest stented lengths (>23 mm) and largest diameters (>3.4 mm).
منابع مشابه
The stenting strategy of drug-eluting stents for coronary artery disease in patients on dialysis
BACKGROUND Reports regarding the relationship between the length and diameter of implanted drug-eluting stents and clinical and angiographic outcomes in dialysis patients are limited. AIM We investigated the efficiency of drug-eluting stents for coronary artery disease in patients on dialysis from the viewpoint of stent sizing. METHODS Sirolimus-eluting stents were implanted in 88 lesions a...
متن کاملComprehensive meta-analysis on drug-eluting stents versus bare-metal stents during extended follow-up.
BACKGROUND Several observational reports have documented both increased and decreased cardiac mortality or Q-wave myocardial infarction with drug-eluting stents compared with bare-metal stents. METHODS We sought to evaluate the safety and efficacy of drug-eluting stents compared with bare-metal stents early after intervention (<1 year) and late (>1 year) among a broad population of patients, ...
متن کاملDrug-eluting versus bare-metal stents in large coronary arteries.
BACKGROUND Recent data have suggested that patients with coronary disease in large arteries are at increased risk for late cardiac events after percutaneous intervention with first-generation drug-eluting stents, as compared with bare-metal stents. We sought to confirm this observation and to assess whether this increase in risk was also seen with second-generation drug-eluting stents. METHOD...
متن کاملRationale and design for the PAINT randomized trial.
BACKGROUND We describe the rationale and design for the 'PercutAneous INTervention with biodegradable-polymer based paclitaxel-eluting or sirolimus-eluting versus bare stents for de novo coronary lesions - PAINT trial'. OBJECTIVES To evaluate two novel formulations of paclitaxel-eluting stent and the sirolimus-eluting stent against a stent with the same metallic structure but without polymer ...
متن کاملDifferential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents.
BACKGROUND Although effective coverage of challenging coronary lesions has warranted the use of overlapping drug-eluting stents, the histopathological response to stent overlap is unknown. METHODS AND RESULTS The arterial reaction to overlapping Cypher or Taxus drug-eluting stents was examined in rabbits with bare metal stents, BxVelocity or Express, serving as controls. Single iliac artery b...
متن کاملImmunosuppressive therapy and tolerance of organ allografts.
Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23. Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-31. Pfisterer M, Brunner-La Rocca HP, Buser PT, et al. Late clinical events after ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 2 1 شماره
صفحات -
تاریخ انتشار 2009