Biomechanical Evaluation of Diagonal Transfixation in Pedicle Screw Instrumentation

نویسندگان

  • Tae-Hong Lim
  • Jesse Kim
  • Timothy Yoon
  • Atsushi Fujiwara
چکیده

In pedicle screw instrumentation, it is common to use one or more transfixators that crosslink the longitudinal rods horizontally. Such a horizontal transfixation (HTF) of the longitudinal rods was shown to provide an additional stability in axial rotation and lateral bending but not in flexion extension. Most significant contribution of HTF was noted in axial rotational stability because the torsional instability appeared to be most difficult to prevent using pedicle screw fixation. Recently, diagonal transfixation (DTF) has been suggested as a way to improve the overall biomechanical rigidity of the pedicle screw systems. However, the construct stiffness changes due to DTF has not been well investigated yet. The purpose of this study was to investigate biomechanical advantages of DTF compared with the HTF using flexibility tests and finite element (FE) analyses.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Physical characteristics of polyaxial-headed pedicle screws and biomechanical comparison of load with their failure.

STUDY DESIGN Pedicle screw strength or load to failure was biomechanically evaluated, and the geometric characteristics of pedicle screw instrumentation systems were compared. OBJECTIVES To compare the features of pedicle screw systems, and to demonstrate the failure point of the polyaxial pedicle screw head. SUMMARY OF BACKGROUND DATA Many pedicle screw instrumentation systems are currentl...

متن کامل

Biomechanical Evaluation of Pedicle Screw-Based Dynamic Stabilization Devices for the Lumbar Spine: A Systematic Review

STUDY DESIGN This study is a systematic review of published biomechanical studies involving pedicle screw-based posterior dynamic stabilization devices (PDS) with a special focus on kinematics and load transmission through the functional spine unit (FSU). METHODS A literature search was performed via the PubMed online database from 1990 to 2008 using the following key words: "biomechanics," "...

متن کامل

شکست وسایل تثبیت ستون فقرات

This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...

متن کامل

Biomechanical Evaluation of a Novel Posterior Integrated Clamp That Attaches to an Existing Posterior Instrumentation for Use in Thoracolumbar Revision

STUDY DESIGN An in vitro biomechanical study. PURPOSE To evaluate the biomechanics of a novel posterior integrated clamp (IC) that extends on an already implanted construct in comparison to single long continuous bilateral pedicle screw (BPS) and rod stabilization system. OVERVIEW OF LITERATURE Revision surgery in the thoracolumbar spine often necessitates further instrumentation following ...

متن کامل

Biomechanics of grade I degenerative lumbar spondylolisthesis. Part 2: treatment with threaded interbody cages/dowels and pedicle screws.

OBJECT The authors sought to determine the biomechanical effectiveness of threaded interbody cages or dowels compared with that achieved using pedicle screw instrumentation in resisting Grade I lumbar spine degenerative spondylolisthesis. METHODS Thirty-three levels obtained from seven cadaveric lumbar spines were instrumented with cages or dowels, pedicle screw/rod instrumentation, or both. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000