A trial of objective visual field measurement by pupillary reaction
نویسنده
چکیده
We created pupil perimetry that could objectively analyze the visual fields utilizing the light reflex with the Visual Evoked Response Imaging System (VERIS). Nineteen hexagonal stimulating elements were used to stimulate up to 15 degrees of eccentricity at 2 Hz. The evoked light reflex was recorded by the infrared camera, and the changes in the maximum transverse diameter of the pupil were measured using a pupillometer. Then, the amplitude of the light reflex evoked by local retinal stimulation was calculated using VERIS Science 4.1. The variation coefficient of the light reflex was the smallest in healthy individuals and its amplitude was greatest when white-black stimuli were delivered with an indoor luminance of 5 asb. Therefore, this was established as the optimal testing condition for the present perimetric system. In patients with visual field defects, the amplitude of the light reflex at areas of visual field loss was significantly smaller than that at normal areas, but minute defects could not be detected. Pupil perimetry utilizing VERIS could objectively analyze the visual fields, but the size of the stimulated field must be expanded and the resolution must be improved before it can be used clinically. (Accepted on November 18, 2008)
منابع مشابه
Multifocal pupillary light response fields in normal subjects and patients with visual field defects
The optimal conditions for recording focal pupillary light responses with a multifocal stimulation technique were determined, and the technique was applied to normal subjects and patients with visual field defects. Thirty-seven hexagonal stimuli were presented on a TV monitor with a visual field of 40 degrees diameter under a constant background illumination. Using a slow (4.7 Hz) m-sequence, r...
متن کاملEvaluation of Visual Signs and Symptoms in Patients with Alzheimer's Disease
Background and Objective:Patients with Alzheimer's disease have impaired visual function even in the early stages of the disease. Therefore, the present study aimed to determine the visual signs and symptoms in patients with Alzheimer's disease and compare them with those in the control group. Materials and Methods:This cross-sectional descriptive study was conducted on 19 Alzheimer patients a...
متن کاملA Case of Functional (Psychogenic) Monocular Hemianopia Analyzed by Measurement of Hemifield Visual Evoked Potentials
PURPOSE Functional monocular hemianopia is an extremely rare condition, for which measurement of hemifield visual evoked potentials (VEPs) has not been previously described. METHODS A 14-year-old boy with functional monocular hemianopia was followed up with Goldmann perimetry and measurement of hemifield and full-field VEPs. RESULTS The patient had a history of monocular temporal hemianopia...
متن کاملEffect of nebulized ipratropium bromide on intraocular pressures in children.
STUDY OBJECTIVE To evaluate the effects of nebulized ipratropium bromide on intraocular pressures and pupillary responses in children with asthma. DESIGN A double-blind, randomized, crossover study. SETTING Children's Hospital of Winnipeg, University of Manitoba. PATIENTS OR PARTICIPANTS Age 6 to 17 years with asthma. INTERVENTION Nebulized ipratropium bromide added to albuterol sulfate...
متن کاملAssessment of unilateral afferent pupillary defects by pupillography.
A pupillographic technique, an adaptation of the swinging light test, is described for the measurement of unilateral afferent pupillary defects. In normal persons it yielded accurate, reproducible estimates of the magnitude of artificial afferent defects made with neutral filters of 1 to 4 log units density. In 15 studies on 8 patients with unilateral optic neuritis and 2 with unilateral compre...