Hyperpolarized Gas Polarimetry and Imaging at Low Magnetic Field

نویسنده

  • Tina Pavlin
چکیده

MR imaging with polarized noble gases has shown promise in both, biomedical and material’s imaging applications. Its advantage over the conventional proton MRI lies in its ability to produce high signal-to-noise ratio (SNR), high-resolution images at low magnetic field strengths. In this work: 1. We implemented and studied in detail two methods for detecting hyperpolarization levels of 129Xe and 3He: NMR (Nuclear Magnetic Resonance) and EPR (Electron Paramagnetic Resonance). The 3He NMR and EPR data allowed for a comparison of these two polarimetry methods, while 129Xe NMR and EPR data showed promise for the calibration of 129Xe EPR shifts. 2. We investigated the possibility of using a pulsed resistive low-field MR scanner for spin echo imaging of hyperpolarized gases. By collecting CPMG spin echo trains containing 4096 echoes and lasting over 30 seconds, we demonstrated a high degree of stability for the pulsed resistive low-field scanner. 3. We developed a single-shot PGSE sequence for measuring diffusion coefficients of hyperpolarized gases which removed the effects of background gradients, thus allowing a separation of the TCPMG 2 relaxation from diffusion-induced signal loss. The theoretical estimations of 3He and 129Xe diffusion coefficients which were based on the Lennard-Jones potential agreed well with our measured 3He and 129Xe diffusion coefficients within the experimental errors. 4. We determined the inherent T2 relaxation times of 3He and 129Xe by varying the interecho time in the conventional CPMG spin echo sequence and by modelling the functional dependence of the TCPMG 2 relaxation time on the interecho spacing. 5. We collected first ever 3He gradient echo images on a pulsed resistive low-field scanner. vii In addition, we modelled numerically the effects of flip-angle, diffusion and relaxation rates on signal decay during gradient echo imaging with hyperpolarized gases. 6. We show, with simulations and experiments, that central ordering of RARE k-space acquisition significantly reduces diffusion-induced signal loss. The 1-D RARE images of 3He show a factor of a 100 improvement in the SNR (for 1.6 mm resolution) when using centrally ordered phase-encode gradients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI of the lung gas-space at very low-field using hyperpolarized noble gases.

In hyperpolarized (HP) noble-gas magnetic resonance imaging, large nuclear spin polarizations, about 100,000 times that ordinarily obtainable at thermal equilibrium, are created in 3He and 129Xe. The enhanced signal that results can be employed in high-resolution MRI studies of void spaces such as in the lungs. In HP gas MRI the signal-to-noise ratio (SNR) depends only weakly on the static magn...

متن کامل

Hyperpolarized Noble Gas Mri of the Brain and Lungs

INTRODUCTION We are developing a new diagnostic technology: magnetic resonance imaging (MRI) and spectroscopy of hyperpolarized noble gases. Large non-equilibrium nuclear spin polarizations can be created in the spin-1/2 noble gases, He and Xe, using the technique of spin-exchange optical pumping. Such large polarizations greatly enhance the magnetic resonance detection of He and Xe, enabling h...

متن کامل

Propane-d6 Heterogeneously Hyperpolarized by Parahydrogen

Long-lived spin states of hyperpolarized propane-d6 gas were demonstrated following pairwise addition of parahydrogen gas to propene-d6 using heterogeneous parahydrogen-induced polarization (HET-PHIP). Hyperpolarized molecules were synthesized using Rh/TiO2 solid catalyst with 1.6 nm Rh nanoparticles. Hyperpolarized (PH ∼ 1%) propane-d6 was detected at high magnetic field (9.4 T) spectroscopica...

متن کامل

High-Resolution Low-Field Molecular Magnetic Resonance Imaging of Hyperpolarized Liquids

We demonstrate the feasibility of microscale molecular imaging using hyperpolarized proton and carbon-13 MRI contrast media and low-field (47.5 mT) preclinical scale (38 mm i.d.) 2D magnetic resonance imaging (MRI). Hyperpolarized proton images with 94 × 94 μm(2) spatial resolution and hyperpolarized carbon-13 images with 250 × 250 μm(2) in-plane spatial resolution were recorded in 4-8 s (large...

متن کامل

Signal-to-noise ratio for hyperpolarized ³He MR imaging of human lungs: a 1.5 T and 3 T comparison.

The signal-to-noise ratio in hyperpolarized noble gas MR imaging is expected to be independent of field strength at frequencies typical of clinical systems (e.g., 1.5 T), where body noise dominates over coil noise. Furthermore, at higher fields (e.g., 3 T), the SNR of lung images may decline due to decreases in T(2) originating from increases in susceptibility-induced field gradients at the air...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003