Parametric Blind Deconvolution for Confocal Laser Scanning Microscopy (CLSM)-Proof of Concept

نویسندگان

  • Praveen PANKAJAKSHAN
  • Laure BLANC-FÉRAUD
  • Bo ZHANG
  • Zvi KAM
  • Jean-Christophe OLIVO-MARIN
  • Josiane ZERUBIA
چکیده

We propose a method for the iterative restoration of fluorescence Confocal Laser Scanning Microscope (CLSM) images with parametric estimation of the acquisition system’s Point Spread Function (PSF). The CLSM is an optical fluorescence microscope that scans a specimen in 3D and uses a pinhole to reject most of the out-of-focus light. However, the quality of the image suffers from two primary physical limitations. The first is due to the diffraction-limited nature of the optical system and the second is due to the reduced amount of light detected by the photomultiplier tube (PMT). These limitations cause blur and photon counting noise respectively. The images can hence benefit frompost-processing restoration methods based on deconvolution. An efficient method for parametric blind image deconvolution involves the simultaneous estimation of the specimen 3D distribution of fluorescent sources and the microscope PSF. By using a model for the microscope image acquisition physical process, we reduce the number of free parameters describing the PSF and introduce constraints. The parameters of the PSF may vary during the course of experimentation, and so they have to be estimated directly from the observation data. We also introduce a priori knowledge of the specimen that permits stabilization of the estimation process and favorizes the convergence. Experiments on simulated data show that the PSF could be estimated with a higher degree of accuracy and those done on real data show very good deconvolution results in comparison to the theoretical microscope PSF model. Key-words: Confocal Laser Scanning Microscope (CLSM), Bayesian restoration, blind deconvolution, Point Spread Function (PSF), Richardson-Lucy (RL), Total Variation (TV), parameter estimation ∗ ARIANA Project-team, CNRS/INRIA/UNSA, 2004 Route des lucioles-BP93, 06902 Sophia-Antipolis Cedex, France † Quantitative Image Analysis Unit, Institut Pasteur, 25-28 rue du Docteur Roux, 75015 Paris, France ‡ Department of Molecular Cell Biology, Weizmann Institute of Science, Rehovot, Israel 76100. Déconvolution aveugle paramétrique en imagerie de Microscopie Confocale à Balayage Laser (CLSM). Résumé : Nous proposons une méthode de restauration itérative d’images de fluorescence CLSM et d’estimation paramétrique de la fonction de flou (PSF) du système d’acquisition. Le CLSM est un microscope qui balaye un échantillon en 3D et utilise une sténopée pour rejeter la lumière en dehors du point de focalisation. Néanmoins, la qualité des images souffre de deux limitations physiques. La première est due à la diffraction due au système optique et la seconde est due à la quantité réduite de lumière détectée par le tube photo-multiplicateur (PMT). Ces limitations induisent respectivement un flou et du bruit de comptage de photons. Les images peuvent alors bénéficier d’un post-traitement de restauration fondé sur la déconvolution. Le problème à traiter est l’estimation simultanée de la distribution 3D de l’échantillon des sources fluorescentes et de la PSF du microscope (i.e. de déconvolution aveugle). En utilisant un modèle de processus physique d’acquisition d’images microscopiques (CLSM), on réduit le nombre de paramètres libres décrivant la PSF et on introduit des contraintes. On introduit aussi des connaissances a priori sur l’échantillon ce qui permet de stabiliser le processus d’estimation et de favoriser la convergence. Des expériences sur des données synthétiques montrent que la PSF peut être estimée avec précision. Des expériences sur des données réelles montrent de bons resultats de déconvolution en comparaison avec le modèle théorique de la PSF du microscope. Mots-clés : Microscopie Confocale à Balayage Laser (CLSM), restauration Bayésienne, déconvolution aveugle, la fonction de flou (PSF), Richardson-Lucy (RL), Variation Totale (TV), estimation paramétrique Parametric Blind Deconvolution for Confocal Laser Scanning Microscopy (CLSM) i

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Blind Deconvolution in 3d Biological Microscopy

Confocal microscopy o ers several advantages over conventional optical microscopy with its small depth-ofeld, its reduction of out-of-focus blur, and its full three-dimensional (3D) image scanning ability. For biomedical applications, it can also acquire images of living cells, usually labeled with one or more uorescent probes. The confocal laser scanning microscope (CLSM) is an optical uoresce...

متن کامل

On blind deconvolution for thin layered confocal imaging

In this paper, we have proposed an Alternate Minimization (AM) algorithm for estimating the Point-Spread Function (PSF) of a Confocal Laser Scanning Microscope (CLSM) and the specimen fluorescence distribution. A 3-D separable Gaussian model is used to restrict the PSF solution space and a constraint on the specimen is used so as to favor the stabilization and convergence of the algorithm. The ...

متن کامل

Towards many colors in FISH on 3D-preserved interphase nuclei.

The article reviews the existing methods of multicolor FISH on nuclear targets, first of all, interphase chromosomes. FISH proper and image acquisition are considered as two related components of a single process. We discuss (1) M-FISH (combinatorial labeling + deconvolution + wide-field microscopy); (2) multicolor labeling + SIM (structured illumination microscopy); (3) the standard approach t...

متن کامل

O-21: Differential Expression and Epigenetic Pattern of HOX Family Genes in Cumulus Cells of Mature MII Oocytes from Patients with Polycystic Ovary Syndrome

Background Ovarian tissue cryopreservation represents a promising strategy to preserve the ovarian function in cancer patients. It is usually performed by slow freezing/rapid thawing (SF/RT). Recent studies emphasize an ultrarapid cryopreservation procedure, vitrification/warming (V/W), since it might prevent damages due to ice crystal formation. Comparative studies between the cryopreservation...

متن کامل

In vivo oral biofilm analysis by confocal laser scanning microscopy: methodological approaches

The scientific community is showing an increasing interest in exploring the in vivo formation of the undisturbed human oral biofilm, because understanding the processes involved may open new avenues for interfering with the pathogenic properties of biofilms. The present chapter is focused on in vivo human models of undisturbed oral biofilm analysed by confocal laser scanning microscopy (CLSM). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008