Partial Discharges in Low-Voltage Cables
نویسندگان
چکیده
Testing of high voltage apparatus for partial discharges has long been recognized as an important part of quality control for these devices. Recently, interest has been focused on methods for testing low voltage cables to determine their integrity under adverse operating conditions such as a loss of coolant accident. A new method, utilizing partial discharges, is presented which has the potential for locating breaches in the insulat,ion of in situ, low voltage, multi-conductor cables. I N T R O D U C T I O N Cables used in power plants are selected on the basis of qualification tests [l] which provide a sufficient degree of confidence in the ability of the cables to maintain operational readiness for a well-defined "life" duration. As the cables age under the various environmental stresses prevailing in a power plant, nuclear plants in particular, the question arises of how much "residual life" exists in the cables as they approach their rated, qualified life. There is considerable interest in assessing this readiness, and a number of investigators have proposed various test methods [2]. In particular, a method that could allow nondestructive, in situ assessment would be extremely valuable. The detection of partial discharges at identifiable sites along a cable offers a method for assessing the likelihood of a fault to occur during a loss of coolant accident on a cable containing an incipient defect. Such an incipient defect might be a breach of the insulation that would remain undetected under normal operating conditions. Low-voltage cables, in contrast with cables designed for highvoltage service, arc not provided with an insulation structure aimed at making them free from partial discharges under modelate overvoltage conditions such as the application of a test voltage. Therefore, the occurrence of a partial discharge at an incipient defect site has to be differentiated from tlie background of the expected partial discharges that will occur over the length of the cable in the absence of any significant defcct. The test method described in this paper offers the opportunity to make this differentiation and locate the discharge sites associated with insulation breaches. Three representative types of cables in which artificial defects had been created were subjected to the test; every defect was successfully located. P R I N C I P L E O F T H E M E T H O D Partial discharges will occur along the entire length of a cable when voltages greater than the partial discharge inception voltage are applied. To develop a strategy for analyzing experimental data from a cable that also contains defects resulting in partial discharges at specific sites, several assumptions need to be made. The first is that there are no preferred partial discharge sites in the cable under test. Therefore, it would be expected that, ideally and in the absence of any defect, the partial discharges would be uniformly distributed along the length of the cable. F.D. Martzloff National Institute of Standards and Technology Gaithersburg, MD 20899 The second assumption is that, in the absence of a defect, the partial discharge pulses occur as random events in time, i.e., the observed process is a marked random point process [3]. Using these assumptions causes the observed partial discharge process to resemble, asymptotically, a Poisson shot noise process [3,4], with pulses emanating from all positions along the cable. If a sample of data werc analyzed by calculating a histogram of the positions from which each pulse in the sample emanated, then, using this model, the histogram would correspond to a uniform distribution. The third assumption is that amplitudes of the pulses, expressed in units of charge at each partial discharge site, are gammadistributed [4] with the parameters of the probability density being independently and identically distributed. The observed probability density of the charge will then have the form where p(q) is the probability density of the observed charge in the entire cable, p(q/z, w) is a conditional probability density of the charge at a single site, p(z) is the probability density of the locations of the partial discharge sites along the cable and p(w) is the probability density of the parameter w, such as the degree of imperfection in the insulation (local field enhancements) that control the most probable discharge amplitude q at that site. By assu~nption, there is no preferred site and experimental evidence indicates that the physic~l behavior at each site is similar. This suggests that the superposition of these infinitesimal processes will yield a seemingly well behaved, predominantly unimodal probability dcnsity for the charge and this has been observed experimentally. Now consider the modcl for a defect. The goal of this measurement technique is to detect an insulation flaw which is defined, for these purposes, as a conlplete crack through the insulation to the conductor. Partial discharge in electrode arrangements that consist of a conductor-conductor interface or conductor-dielectric interface is often more active than when the electrodes are a dielectric-dielectric interface. The implication is that tlie partialdischarge sites at the flaws will be more active than the sites in the rest of the cable and consequently cause significant deviations from the ideal model. The basic idea of the nleasurement technique is to identify whether the data significantly deviate from t,he behavior defined by cquation (1). In this case, equation (1) is modifird by adding a term in which p(w) is replaced by p(wlz) where w depends on z and is highly localized to particular points z,. .4dmittcdly, thc model is a gross idcalization of the cxprcted U.S. Government work not protected by U.S. copyright Figure 1. Block diagram of partial discharge detection and recording. behavior, however, the general concept has merit if the defects do behave differently from the normal background partial discharge in the cable. In practice, there will be naturally occurring, preferred partial discharge sites that are not flaws but cause variations in the expected background count rates. In fact two such preferred locations have already been identified, the ends of the cable. E X P E R I M E N T A L A P P A R A T U S The experimental apparatus implemented is a general purpose system designed for acquiring broadband partial discharge waveforms and processing the acquired signals as shown in the block diagram of Figure 1. The key elements are the high-voltage system, the coupling circuit and the data acquisition and analysis system. The high-voltage system used to apply the necessary voltages to the cables under test consists of a 60 Hz high-voltage transformer with appropriate noise filtering. Measurements on the cables are made at voltage levels exceeding the partial discharge inception voltage by 10, 20, and 40 percent. The inception level is defined as that voltage which causes at least one partial discharge pulse above a specified charge level q per second. The partial discharge signals are coupled from the cable under test to the measurement system through a coaxially mounted, 1 n F capacitor. The capacitor is the first element in a high-pass filter having a lower cutoff frequency of 30 kHz and a 1000 0 input impedance. Initial testing with sensitivities ranging down to 0.05pC did not produce useful results because the partial discharge magnitudes at inception are in excess of 10 pC. Since the predominant partial discharge levels are greater than 10pC, an attenuator and input protection are included in the circuit which limits the input sensitivity to 1 pC. The capacitance of the input protection limits the bandwidth of the system to approximately 10 MHz. This input bandwidth is adequate for these experiments since the cables under test are lossy and limit the usable bandwidth to within this range. A variable attenuator is included between the input preamplifier and the gain block of the system to provide amplitude scaling which prevents saturation of the amplifier for larger partial discharge amplitudes. Partial discharge pulses are recorded using a LeCroy 9400A1 digital oscilloscope which has an 8-bit digitizer that can sample 32 000 'The identification of commercial materials and their sources is made to describe the experiment adequately. In no case does this identification imply rcommendation by the National Institute of Standards and Technology, nor does it imply that the instrument is the best available. points at a 100 MHz rate. The advantage of using this oscilloscope is its ability to segment its 32 kB acquisition memory so that it can acquire up to 250 separate waveforms at its maximum sampling rate before having to transfer them to a computer over an IEEE 488 interface. The computer is a PC-AT class computer. The ASYST' scientific software package is used for acquisition control and data analysis. Up to 20000 waveforms can be collected before the available disk space limits the computer's ability to process the data; typically 5000 waveforms are collected. Active data collection occurrs only during a few seconds of the voltage application to the cable under test, however, voltage is typically applied for 8 minutes since the high voltage system is not under control of the computer and time is needed to archive the data. Since the system uses a computer with only moderate computational ability, all processing has to be performed off line. M E A S U R E M E N T S Two fundamental estimates are made from each recorded waveform: an estimate of the charge, and an estimate of the location of the partial discharge site in the cable. It would be desirable to calculate estimates for all detectable pulses; however, since the measurement system is general purpose, trade-offs for cost, speed, and data handling capabilities have been made. With these constraints, only a limited number of waveforms can be collected and analyzed. The method used to calculate the charge in the partial discharge waveform is the same as that used in [4] and has been shown to be more accurate than the usual measurement of the peak value of the pulse. The technique uses the pulse energy derived from the waveform to develop an estimate of the charge and assumes that the measured partial discharge waveform is similar to calibration pulses injected into the cable. The calibration pulses are generated by applying a fast-rise step of known amplitude through a known capacitance into the cable under test. Further corrections in the estimates to account for the cable attenuation were not deemed necessary. If the flaw is detectable, then the histogram of the charge will no longer be unimodal. Using this fact, the measurement can be enhanced by setting a lower discrimination level so that the instrument measures only those partial discharges which appear to be anomalous. The lower discrimination level is also referred to as the trigger level, the level which the partial discharge pulse must exceed to initiate the recording cycle of the digital oscilloscope. The basic principle used to determine the location of the partial discharge can be understood by referring to Figure 2. When a partial discharge pulse originates at some point interior to a cable it splits evenly into two pulses which travel in opposite directions. One pulse, referred to as the direct pulse, proceeds toward the detector end arriving at time t,. The other pulse proceeds toward the open end of the cable and is reflected from the open circuit back toward the detector end, arriving at the detector at time t 2 . Knowing the velocity of propagation, v, for the cable, the location, e, is given by where the location is referenced from the open circuit end of the cable. To save time in processing, a simple but accurate method is used to calculate the locations. The technique applies an approximate matched filter to the recorded p l s e s whose shape resembles a DISCHARGE DETECTOR SITE EN0 -AOPEN END Figure 2. Position versus time diagram of direct pulse and reflected pulse propagation. partial discharge pulse. In effect, this assumed pulse is crosscorrelated with the pulses in the measured data. The time delay between the two largest pulses in the waveform is determined and converted into a location using a measured propagation velocity. More accurate delay estimators are not justified since the increased computational effort does not provide enough increase in accuracy. When the two largest pulses in the data record are from two distinct discharge sites, the estimate is referred to as a phantom delay. The probability of calculating a phantom delay is small at the voltage levels used, with less than 1 percent of the estimates being phantoms. These phantoms are not a problem since the time delay between the pulses is random and does not lead to a count rate that favors any particular site. A limitation of this technique is the existence of a measurement blind spot in the cable: when the arrival times of the direct pulse and reflected pulse are nearly the same, it becomes difficult to differentiate between a single pulse and two closely spaced pulses. Without special, computationally intensive processing, these sites all appear to be at a distance range near the end of the cable, in effect creating a blind spot.
منابع مشابه
On the electrodynamics of partial discharges in voids in solid dielectrics
Until1 now paper 3-phase belt type cables were succesfully used for voltages upto 20 kV in great parts of the world. Replacement of paper by extruded insulation has been unsuccesfull and service voltages no higher than 5 kV can be applied because of the large discharges and uncontrolled field in the interstices at the core and the belt. Belt-type cables remained paper-insulated for that reason....
متن کاملContinuous On-line Condition Monitoring of HV Cable Systems
This paper discusses data acquisition, transmission and processing methodologies for continuous on-line monitoring of partial discharges in high voltage cable systems. A PD continuous on-line monitoring system for underground cable circuits using capacitive couplers, LiNbO3 electro-optic modulators, laser, optical switch and optical fibers has been developed. Future research will consider effec...
متن کاملAdvanced technique for partial discharge detection and analysis in power cables
Polymeric cables are the most common choice for transmission and distribution in populated areas, as well as for the connection of components (transformers, GIS, etc.) in new power stations, replacing paper-oil cables. Indeed, they do possess superior characteristics with respect to oil-filled cables. As an example, they do require lower maintenance, they are lighter (easier to deploy) and, in ...
متن کاملPartial discharges in cylindrical cavities at variable frequency of the applied voltage
Measurements of partial discharges are commonly used to diagnose the insulation system in high voltage components. Traditionally a single fixed frequency of the applied voltage is used for such measurements as in the Phase Resolved Partial Discharge Analysis (PRPDA) technique. With the Variable Frequency Phase Resolved Partial Discharge Analysis (VF-PRPDA) technique the frequency of the applied...
متن کاملLean Maintenance model to reduce scraps and WIP in manufacturing system:case study in power cables factory
The aim of this paper is to develop an innovative Lean Maintenance model in order to optimize the process flow and reduce or eliminate scraps and work-in-progress (WIP) in a manufacturing context. To achieve these objectives has been formulated a new method, called Lean Root Cause & Defect Analysis (LRCDA), which merges the process steps of the existing Root Cause & Failure Analysis (RCFA) tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002