Microcalorimetric determination of glucose in reference samples of serum.

نویسنده

  • R N Goldberg
چکیده

Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are compared with the tentative results of analyses obtained by the spectrophotometric hexokinase/glucose-6-phosphate dehydrogenase method and by isotope-dilution mass spectrometry. In most cases, the microcalorimetric results appear to be in agreement with the results obtained by these latter two methods. A discussion of the basis of the microcalorimetric measurements is presented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of serum haptoglobin reference value in clinically healthy Iranian fat-tailed sheep

Blood samples were collected from the jugular vein of 101 clinically healthy Iranian fat-tailed sheep according to their age (5 years) and sex. Serum haptoglobin (Hp) was measured based upon the preservation of the peroxidase activity of haemoglobin, which is directly proportional to the amount of Hp. The reference value for serum Hp of apparently healthy Iranian fat-tailed sheep was 0.05-0.18 ...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Determination of reference ranges using medical laboratory date

In order to have reliable reference ranges and to minimize the effects of variables such as the procedure of specimen collection, geographical location, dietary habits, life style and possible errors during the performance of tests, it  is recommended that each medical laboratory establish it's own reference values. Idealy, the reference ranges Should be determined by analysis of specimens from...

متن کامل

Age-Related Alteration in Serum Adiponectin in Rats and Its Association with Insulin Resistance Markers

Introduction: Adiponectin is one of the most important adipose derived hormone that conflicting data are available about serum changes of adiponectin at different ages.The present study was done to determine the age related changes in serum adiponectin and its association with insulin resistance (IR) indices in aging in male rats. Methods: In this study, serum samples were obtained from male r...

متن کامل

Determination of Kinetic Parameters for Catalytic Isomerization of Glucose to Fructose by immobilized Glucose Isomerase in an Aqueous-Ethanol Medium

Catalytic isomerization of glucose to fructose by immobilized glucose isomerase in an aqueous-ethanol medium was studied. Using Michaelis-Menten equation and Haldane relationship, the main kinetic parameters were determined: Kmf, Vmf, Kmr, Vmr. By comparing the aqueous-ethanol medium with an aqueous solution, the measured values of Kmr and Kmf were increased in the aqueous-ethanol solution, whi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 10  شماره 

صفحات  -

تاریخ انتشار 1976