Suppression of demand pacemakers by inactive pacemaker electrodes.

نویسندگان

  • W D Widmann
  • S Mangiola
  • L A Lubow
  • F M Dolan
چکیده

Ventricular inhibited cardiac pacemakers were suppressed by intimate contact of the tip of the active pacemaker electrode with that of the inactive pacemaker electrode in two patients. This contact apparently was sensed as myocardial electrical activity and resulted in variable suppression of pacemaker emission. There was no interference with R-wave sensing function. The threshold for stimulation was unaffected. There was no loss of capture as tested with the magnet-controlled continuous mode of stimulation. This type of pacemaker failure can be remedied simply by withdrawing the tips of the electrodes from intimate contact.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE ROLE OF PACEMAKER CLINIC IN THE FOLLOW-UP OF PATIENTS WITH PERMANENT PACEMAKERS

The Pacemaker Clinic at Shahid Rajai Cardiovascular Research Center first started operating in August 1992. In its first year of operation, 294 permanent pacemaker patients were studied, allowing an appraisal to be carried out of the clinic's effectiveness in diagnosing and treating early complications. In the final analysis, pacemaker complications were observed in 68 (23%) patients, of wh...

متن کامل

Interference effect of myopotenitals on function of unipolar demand pacemakers.

Of 44 patients with demand pacemakers, 33 had pacemaker rhythm and were examined for failure in pacemaker function produced by myopotentials. Most patients were subjected to a standard experimental programme, with simultaneous recording of electrocardiogram and electromyogram. In 28 of the 33 patients the pacemaker was inhibited by muscle potentials. Three patients had suffered symptoms which c...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

CASE REPORTS Inhibition of Bipolar Demand Pacemaker by Diaphragmatic Myopotentials

INHIBITION OF DEMAND PACEMAKERS by musculoskeletal potentials has been reported to occur only with unipolar pacing systems.1 14 Mymin et al.,2 however, described one case of apparent suppression of a bipolar unit by myopotentials but gave no details about the mechanism of interference. Peter et al.", recently described transient inhibition of a unipolar demand pacemaker during deep respiration ...

متن کامل

Lack of sensing by demand pacemakers due to intraventricular conduction defects.

A previously unrecognized form of failure of normally functioning noncompetitive R-inhibited or R-triggered pacemakers to sense is described in 30 patients. The failure was produced by the delayed arrival of ventricular depolarization due to intraventricular conduction disturbances at the site of pacemaker sensing electrodes. These patinets with late activation of the right ventricle exhibited ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 45 2  شماره 

صفحات  -

تاریخ انتشار 1972