Usefulness of the noncontact mapping system to elucidate the conduction property for the treatment of common atrial flutter.

نویسندگان

  • Masateru Kondo
  • Koji Fukuda
  • Yuji Wakayama
  • Makoto Nakano
  • Yuhi Hasebe
  • Hiroaki Shimokawa
چکیده

BACKGROUND The functional role of the cavotricuspid isthmus (CTI) for common atrial flutter (cAFL) remains to be elucidated. In the present study, we examined whether the EnSite system (St. Jude Medical, St. Paul, MN, USA), a noncontact mapping system, is useful to evaluate the conduction properties of CTI to minimize radiofrequency (RF) ablation applications for cAFL. METHODS We enrolled 22 consecutive patients with cAFL (64.1 ± 9.5 years old, M/F 21/1) treated with the EnSite system and examined the conduction properties during cAFL and during atrial pacing. In addition, the effectiveness of the system was evaluated in comparison with the conventional ablation group (67 ± 8.9 years old, n = 15, M/F 13/2). RESULT In 11 out of the 22 patients, CTI block line was achieved by fewer RF applications on a presumed single activation pathway which the EnSite system showed (point ablation [PA] group), and the remaining 11 patients needed additional linear ablation (additional ablation [AA] group). The number of RF applications in the PA group was significantly smaller than that in the conventional group. During the lower lateral right atrial pacing at a cycle length of 600 ms, the CV of the CTI in the PA group was smaller compared to that in the AA group (1.36 ± 0.61 vs 2.17 ± 0.66 m/s, P < 0.05), although the CV during cAFL (averaged cycle length 245 ± 34 ms) was not different in both groups. CONCLUSIONS These results indicate that targeting the presumed single line identified by EnSite could be an optional therapy for cAFL RF ablation, and diverse conduction properties in CTI are related to the success rate of this procedure. (PACE 2012;35:1464-1471).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Case Report of Neonatal Atrial Flutter with Poor Feeding and Tachypnea

Background: Arrhythmias in neonates are not common and usually affect newborns with a normal heart or those that suffer from structural heart disease. A malignant type of arrhythmias is supraventricular tachycardia. Meanwhile, one uncommon type of supraventricular arrhythmias is atrial flutter (AFL), which is founded upon reentry mechanisms in the atrium. The AFL may result in heart failure or ...

متن کامل

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

Mapping of atrial activation with a noncontact, multielectrode catheter in dogs.

BACKGROUND Endocardial mapping of sustained arrhythmias has traditionally been performed with a roving diagnostic catheter. Although this approach is adequate for many tachyarrhythmias, it has limitations. The purpose of this study was to evaluate a novel noncontact mapping system for assessing atrial tachyarrhythmias. METHODS AND RESULTS The mapping system consists of a 9F multielectrode-arr...

متن کامل

Radiofrequency catheter ablation of common-type atrial flutter guided by conventional versus electroanatomical mapping.

Radiofrequency catheter (RF) ablation aiming the complete conduction block of the cavotricuspid isthmus has become treatment of choice for common type atrial flutter. Different approaches to guide the ablation procedure are used. For the conventional approach multipolar catheters in the right atrium and in the coronary sinus are required to detect the induction of conduction block via the isthm...

متن کامل

A systematic review of the effectiveness of catheter ablation NavX mapping system for treatment of the cardiac arrhythmia

  Background: Catheter ablation is widely used for treatment of atrial fibrillation. The use of fluoroscopic and non-fluoroscopic mapping systems in catheter ablation is common. This study conducted to investigate the safety and effectiveness of Navx non-fluoroscopic mapping system.   Methods : In this study, the appropriate electronic databases including Cochrane Library and Ovid Medline searc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Pacing and clinical electrophysiology : PACE

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 2012