Miniature Personal Ozone Monitor Based on UV Absorbance.

نویسندگان

  • Peter C Andersen
  • Craig J Williford
  • John W Birks
چکیده

A new portable instrument has been developed that offers rapid detection of ozone at the ppb level for personal exposure monitoring. The Personal Ozone Monitor is based on the EPA Federal Reference Method of UV absorbance and has the advantage of being small (10 × 7.6 × 3.8 cm), light-weight (0.3 kg), low power (2.9 watts), and battery-operated. The instrument can be worn by an individual during normal daily activities because it is unaffected by humidity, physical orientation, temperature, and vibration. In order to eliminate any significant interference from water vapor, Nafion(®) tubing was installed before the detection cell, and the optical path was lined with quartz. A precision of 1.5 ppbv and limit of detection of 4.5 ppbv (S/N = 3) was demonstrated with the instrument making measurements every 10 seconds.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of ultraviolet absorbance, chemiluminescence, and DOAS instruments for ambient ozone monitoring.

This paper evaluates the accuracy of ozone measurements made by monitors that determine ozone concentrations in ambient air by UV absorption. These monitors are typically used to measure ozone for the purpose of establishing local compliance to air-quality standards. The study was predicated by the concern that commercially available UV absorbance O3 monitors may be subject to interference from...

متن کامل

Mechanism and elimination of a water vapor interference in the measurement of ozone by UV absorbance.

A water vapor interference in ozone measurements by UV absorption was investigated using four different ozone monitors (TEI models 49 and 49C, Dasibi model 1003-AH, and a 2B Technologies model 202 prototype). In the extreme case of step changes between 0 and 90% relative humidity (RH), a large interference in the range of tens to hundreds of ppbv was found for all instruments tested, with the m...

متن کامل

A method to measure the ozone penetration factor in residences under infiltration conditions: application in a multifamily apartment unit.

Recent experiments have demonstrated that outdoor ozone reacts with materials inside residential building enclosures, potentially reducing indoor exposures to ozone or altering ozone reaction byproducts. However, test methods to measure ozone penetration factors in residences (P) remain limited. We developed a method to measure ozone penetration factors in residences under infiltration conditio...

متن کامل

Conventional and Advanced Water Treatment Processes for the Removal of Endocrine Disruptors and Pharmaceuticals

A suite of target endocrine disruptor compounds (EDCs) and pharmaceuticals and personal care products (PPCPs) were evaluated for removal by several water treatment processes at bench-, pilot-, and fullscale. Over 60 different EDCs and PPCPs were chosen and simultaneously evaluated based on structure, occurrence, and potential health impacts. Treatment processes evaluated include physical (e.g.,...

متن کامل

Removal of pharmaceuticals in WWTP effluents by ozone and hydrogen peroxide

Ozonation to achieve removal of pharmaceuticals from wastewater effluents, with pH values in the upper and lower regions of the typical range for Swedish wastewater, was investigated. The main aim was to study the effects of varying pH values (6.0 and 8.0), and if small additions of H2O2 prior to ozone treatment could improve the removal and lower the reaction time. The effluents studied differ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 82 19  شماره 

صفحات  -

تاریخ انتشار 2010